Breckwell SP22 ECONOMY Series Owner's Manual page 14

Hide thumbs Also See for SP22 ECONOMY Series:
Table of Contents

Advertisement

12
D.
AS A BUILT-IN FIREPLACE
Figures 18 and 19 describe a SP22 installation vent-
ed into either a special chase built outside an outer
wall or a false inside wall. This is especially suited for
new construction or remodeling.
The equipment compartment (sides and rear of the
stove in fireplace) must be enclosed per the applica-
ble electrical standards. This can be accomplished
by the use of Breckwell's panel kit part #A-PANEL-22.
NOTE: Floor protection for Built-in raised hearths
requires a continuous sheet beneath to prevent the
possibility of embers falling through to the combus-
tible floor if cracks or separation should occur in the
finished surface.
The chase dimensions shown are minimums and
must be maintained.
INSTALLATION
SEE "INSERT INSTALLATIONS" FOR
PANEL SURROUND INSTALLATION
THE PANEL SURROUND KIT
(PN C-P22-MED)
ATTACH THE PANEL SURROUND
TO THE PANEL SURROUND TO
THE FACE OF THE FIREPLACE
15"
WITH ONE SCREW.
22"
MIN.
6"
MIN.
8"
MIN.
FLOOR PROTECTOR MUST BE
CONTINUOUS WITH NO JOINTS
*
IF CHOOSING TO VENT HORIZONTALLY THROUGH THE WALL, WE RECOMMEND
TERMINATING VERTICALLY WITH AN ADDITIONAL RUN OF AT LEAST 5 FEET.
22"
34" MIN
6"
MIN.
6"
MANTLE
MIN.
3"
MIN.
OVER 6"
FACING
6"
MAX
12"
MIN.
24"
MIN.
EQUIPMENT
COMPARTMENT
RAISED HEARTH MUST BE BUILT
OF 8" HOLLOW CONCRETE BLOCKS.
FIGURE 19
19
18
FACADE
OPENING
24"
34"
FIGURE 18
LISTED
CHIMNEY
CAP
STORM
COLLAR
CHASE CAP
3"
MIN.
L-VENT ONLY
SIDING
5/8" SHEETROCK
(ENTIRE FACADE)
A 1/4" (OR SMALLER) WIRE MESH
SCREEN MUST BE INSTALLED IN
THIS INSTALLATION TO COVER
THE EQUIPMENT COMPARTMENT.
6"
LISTED
THIMBLE
*
LISTED
CHIMNEY
CAP
OUTSIDE AIR
OUTSIDE AIR MAY BE DRAWN FROM
A VENTILATED CRAWL SPACE.