Electrical Installation - Breckwell Classic Cast SPC4000 Owner's Manual

Hide thumbs Also See for Classic Cast SPC4000:
Table of Contents

Advertisement

ELECTRICAL INSTALLATION

This stove is provided with a 6-foot grounded electrical cord extending from the rear of the stove.
We recommend connecting to a good quality surge protector that is plugged into a standard three-prong, 120V, 60 Hz electri-
cal outlet.
Do NOT connect the unit to a GFCI socket.
Voltage variations can lead to serious performance problems. The stoves electrical system is designed for 120V AC with no more than
5% variation. This company cannot accept responsibility for poor performance or damage due to inadequate voltage. If connected to an
older, two-prong outlet, a separate ground wire should be run to a proper ground (refer this to a qualifi ed technician). Always route the
electrical cord so that it will not come in contact with any hot part of the stove.
SPECIAL MOBIL HOME REQUIREMENTS
WARNING: DO NOT INSTALL IN A SLEEPING ROOM.
NOTE: Installation should be in accordance with the Manufactured Home and Safety Standard (HUD), CFR 3280, Part 24
For installation in a mobile home, an outside source of combustion air must be used
(See "COMBUSTION AIR SUPPLY").
The appliance must be grounded to the steel chassis of the home with 8 Ga. copper wire using a serrated or star washer to penetrate
paint or protective coating to ensure grounding.
The appliance must be securely fastened to the fl oor of the mobile home through the two holes in the rear of the stove using 2, ¼" lag
bolts that are long enough to go through both a hearth pad, if used, and the fl oor of the home. (See fi gure 11)
Refer to "VENTING" for proper exhaust confi gurations
CAUTION:
THE STRUCTURAL INTEGRITY OF THE MO-
BILE HOME FLOOR, WALL AND CEILING/
ROOF MUST BE MAINTAINED.
INS TAL LAT ION
IN S TAL L ATION
BOLT HOLES
FIGURE 11
9