I
NSTALLATION
Several issues must be addressed when selecting a suitable location for your new Mahogany Wood Stove.
Observing required clearances to combustible materials, the proximity to a safe chimney, and electrical supply
(if optional blower in use) must all be considered. In addition, selecting a location that takes advantage of the
building's natural air flow is also desirable to maximize the heating effectiveness of the stove. In many cases,
though not all, this is a central location within the building.
Stove Specifications and Performance
Combustion System:
EPA Grams per Hour:
Heat Output (BTU's/per hour:
Exhaust Diameter:
Width:
Depth:
Weight:
When used as a Freestanding Model
Height with Log Storage
Pedestal:
Height with Standard Pedestal:
Clearances
Freestanding Model
The stove must be placed on continuous (grouted
joints) noncombustible material such as ceramic tile,
cement board, brick, 3/8" millboard or equivalent ¼"
material with a k+ .84 insulation factor, or other
approved or listed material suited for floor protection.
Check local codes for approved alternatives.
Clearances for floor protection are measured from the
sides, back, and face (door opening) as shown in
Figure 1.
NOTE: For Canadian installations you are required to
have 18" in front of the stove and 8" from the sides.
The hearth pad for Canadian installations must have
minimum dimensions of 46" x 41".
NOTE: For some insert installations you may be
required to use a hearth extension in order to meet
required clearances. If so, the extensions must meet
the same criteria as the hearth.
America's Favorite Stoves Since 1980
Non‐Catalytic
2.28
9,500 – 37,000
6"
25"
22‐1/2"
430 lbs.
37‐1/8" to Front
38‐13/16" to
Shroud
31‐1/4" to Front
32‐7/8" To Shroud
Heating Capacity:
Approximate Burn Time:
Log Length:
When used as an Insert Model
Height with Large Flashing:
Height with Medium Flashing:
Height of unit inside fireplace:
Height of Stove:
Width with Medium Flashing:
Width with Large Flashing:
Depth Inside of Fireplace:
Chapter 1
Specifications & Clearances
Up to 1,800 sf
7 – 9 Hours
18"
32‐1/16"
30‐1/16"
20‐1/2"
18‐13/16"
42"
48‐1/2"
15"
Figure 1
Page 5