I
NSTALLATION
Several  issues  must  be  addressed  when  selecting  a  suitable  location  for  your  new  Mahogany  Wood  Stove.  
Observing required clearances to combustible materials, the proximity to a safe chimney, and electrical supply 
(if optional blower in use) must all be considered.  In addition, selecting a location that takes advantage of the 
building's natural air flow is also desirable to maximize the heating effectiveness of the stove.  In many cases, 
though not all, this is a central location within the building. 
Stove Specifications and Performance 
Combustion System: 
EPA Grams per Hour: 
Heat Output (BTU's/per hour: 
Exhaust Diameter: 
Width: 
Depth: 
Weight: 
When used as a Freestanding Model 
Height with Log Storage 
Pedestal: 
Height with Standard Pedestal: 
 

Clearances

 
Freestanding Model 
The  stove  must  be  placed  on  continuous  (grouted 
joints)  noncombustible  material  such  as  ceramic  tile, 
cement  board,  brick,  3/8"  millboard  or  equivalent  ¼" 
material  with  a  k+  .84  insulation  factor,  or  other 
approved or listed material suited for floor protection.  
Check  local  codes  for  approved  alternatives.  
Clearances for floor protection are measured from the 
sides,  back,  and  face  (door  opening)  as  shown  in 
Figure 1. 
 
NOTE:  For Canadian installations you are required to 
have 18" in front of the stove and 8" from the sides.  
The hearth pad for Canadian installations must have 
minimum dimensions of 46" x 41". 
 
NOTE:  For some insert installations you may be 
required to use a hearth extension in order to meet 
required clearances.  If so, the extensions must meet 
the same criteria as the hearth. 
America's Favorite Stoves Since 1980 
 
Non‐Catalytic
2.28
9,500 – 37,000
6" 
 
 
25"
22‐1/2"
430 lbs.
 
 
37‐1/8" to Front
 
38‐13/16" to 
Shroud 
31‐1/4" to Front
 
32‐7/8" To Shroud
 
 
 
 
 
 
Heating Capacity: 
Approximate Burn Time: 
Log Length: 
When used as an Insert Model
Height with Large Flashing: 
Height with Medium Flashing: 
Height of unit inside fireplace: 
Height of Stove: 
Width with Medium Flashing: 
Width with Large Flashing: 
Depth Inside of Fireplace: 
 
 
Chapter 1 
Specifications & Clearances 
Up to 1,800 sf
7 – 9 Hours
18"
   
   
   
   
   
   
32‐1/16"
30‐1/16"
20‐1/2"
18‐13/16"
42"
48‐1/2"
15"
Figure 1 
 
Page 5 