LUXURY SERIES SP2700
OWNER'S MANUAL
• WARNING: IF YOUR APPLIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RE-
SULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
PLEASE read this entire manual before installation and use of this pellet fuel-burning
room heater. Failure to follow these instructions could result in property damage, bodily
injury, or even death.
• Save these instructions.
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
Version française est disponible pour téléchargement à partir du site Web de la Poêle US: http://www.breckwell.com
This unit is not intended to be used as a primary source of heat.
French version is available for download from the U. S. Stove website: http://www.breckwell.com
U.S. Environmental Protection Agency
Certified to comply with 2015 particulate emissions standards.
227 Industrial Park Road P.O. Box 151
South Pittsburg, TN 37380
(800) 750-2723 • www.breckwell.com
Breckwell
©BRECKWELL HEARTH PRODUCTS
10/2013
852189C-1904E

Advertisement

Table of Contents
loading

Summary of Contents for Breckwell LUXURY SERIES SP2700

  • Page 1 This unit is not intended to be used as a primary source of heat. French version is available for download from the U. S. Stove website: http://www.breckwell.com Version française est disponible pour téléchargement à partir du site Web de la Poêle US: http://www.breckwell.com U.S. Environmental Protection Agency Certified to comply with 2015 particulate emissions standards.
  • Page 2 6,569 to 34,785 Btu/hr.” Thank you for purchasing the Breckwell Pellet Burning Stove, you are now prepared to burn wood in the most effi cient, convenient way possible. To achieve the safest, most effi cient and most enjoyable performance from your stove, you must do three things: 1) Install it properly;...
  • Page 3 You may use an envelope if you choose. You may register online by going to www.breckwell.com All information submitted will be kept strictly confi dential. Information provided will not be sold for advertising purposes.
  • Page 4   Fold Here Fold Here PLACE STAMP HERE United States Stove Company P.O. Box 151 South Pittsburg, TN 37380...
  • Page 5: Safety Precautions

    Check with local building offi cials. stove. Breckwell Hearth Products grants no warranty, The exhaust system should be checked, at a mini- implied or stated, for the installation or mainte-...
  • Page 6: Installation

    Access to the rear of the stove is necessary. NOTE: Normally, your dealer will perform these functions. CLEARANCES The Breckwell SSP2700 Freestanding has been tested and listed for installation in residential, mo- bile home and alcove applications. FLOOR PROTECTION: Freestanding installa- tions, minimum 24”...
  • Page 7: Combustion Air Supply

    VENTING The Breckwell SP2700 is certifi ed for use with listed TYPE L-Vent, 3” or 4” diameter in size. The stove was tested with Simpson Duravent brand. Class “A” chimney is not required.
  • Page 8: Equivalent Vent Length (Evl)

    INSTALLATION INSTALLATION EQUIVALENT VENT LENGTH (EVL) The longer the run of pipe in your installation, the more restriction there is in the system. Therefore, larger diameter pipe should be used. • Use 4” pipe if you have more than 15 feet of equivalent vent length. •...
  • Page 9: Vertically With New Chimney System

    INSTALLATION INSTALLATION B. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 7) NOTE: Follow L-Vent chimney manufacturer’s instructions. OPTION: To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to offset the pipe from the exhaust outlet to the rear center of the stove.
  • Page 10: Installation Through Side Of Masonry Chimney

    Voltage variations can lead to serious performance problems. The Breck- well electrical system is designed for 120V AC with no more than 5% variation. Breckwell cannot accept responsibility for poor performance or damage due to inadequate voltage. If connected to an older, two-prong outlet, a separate ground wire should be run to a proper ground (refer this to a qualifi...
  • Page 11: Operation

    OPERATION OPERATION PANEL CONTROLS (See Figure 11) The blowers and automatic fuel supply are controlled from a panel on the left-hand side of FIGURE 11 the SP2700. The control panel functions are as follows. ON/OFF SWITCH • When pushed the stove will automatically ignite. No other fi restarter is necessary. The igniter will stay on for at least 10 and up to 15 minutes, depending on when Proof of Fire is reached.
  • Page 12: Proper Fuel

    You will have to empty the burnpot plus vacuum the entire system more often. Poor quality pellets could damage the auger. Breckwell cannot accept responsibility for damage due to poor quality pellets. Your dealer can recommend a good quality pellet dealer in your area.
  • Page 13: Opening Door

    SHUTDOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the “On/Off” control panel switch. The red light will go out. The blowers will con- tinue to operate until internal fi rebox temperatures have fallen to a preset level.
  • Page 14: Operating Safety Precautions

    Pellets should be stored in a dry place. The pellets should not be stored within 12” of the stove. DO NOT STORE OR USE FLAMMABLE LIQUIDS, ESPECIALLY GASOLINE, IN THE VICINITY OF YOUR BRECKWELL STOVE. NEVER USE A GAS OR PROPANE TORCH, GASOLINE, GASOLINE-TYPE LANTERN FUEL, KEROSENE, CHAR- COAL LIGHTER FLUID OR SIMILAR FLUIDS TO START OR “FRESHEN UP”...
  • Page 15: Thermostat Installation

    A thermostat may help you maintain a constant house temperature automatically. A millivolt thermostat is required. A fi xed wall mount or Breckwell’s hand held model can be used. The control panel can be set up two ways to operate your stove in thermostat mode.
  • Page 16: Maintenance

    MAINTENANCE MAINTENANCE FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RE- SULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT. NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly. ASH REMOVAL Ashes should be placed in a metal container with a tight-fi...
  • Page 17 MAINTENANCE MAINTENANCE CLEANING Heat Exchange Tubes – Your Breckwell stove is designed with a built-in heat exchange tube cleaner. This should be used every two or three days to re- move accumulated ash on the tubes, which reduces the effi ciency of your unit. Insert the handle end (with hole) of the cleaning tool onto the cleaning rod (refer to fi...
  • Page 18: Chimney Cleaning

    While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the doorframe. Dispose of all broken glass properly. Return the damaged door to your Breckwell Dealer for repair or replacement.
  • Page 19: Troubleshooting Guide

    TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE When your stove acts out of the ordinary, the fi rst reaction is to call for help. This guide may save time and money by en- abling you to solve simple problems yourself. Problems encountered are often the result of only fi ve factors: 1) poor fuel; 2) poor operation or maintenance;...
  • Page 20 TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE STOVE SHUTS OFF AND THE #3 LIGHT FLASHES Possible Causes: Possible Remedies: (Unplug stove fi rst when possible) The hopper is out of pellets. Refi ll the hopper The air damper is too far open for a low feed If burning on the low setting, you may need to close the damper setting.
  • Page 21: Smoke Smell Coming Back Into The Home

    TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE STOVE FEEDS PELLETS, BUT WILL NOT IGNITE Possible Causes: Possible Remedies: Air damper open too far for ignition. Push the air damper in closer to the side of the stove for startup. In some situations, it may be necessary to have the damper completely closed for ignition to take place.
  • Page 22 TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE STOVE WILL NOT FEED PELLETS, BUT FUEL FEED LIGHT COMES ON AS DESIGNED Possible Causes: Possible Remedies: Fuse on control board blew. Remove the control board. On the back, there is one fuse. If it appears to be bad, replace it with a 5 Amp 125 Volt fuse. Plug the stove back in and try to run the unit.
  • Page 23 TROUBLESHOOTING GUIDE TROUBLESHOOTING GUIDE GLASS “SOOTS” UP AT A VERY FAST RATE FLAME IS LAZY, DARK AND HAS BLACK TIPS AFTER STOVE HAS BEEN ON FOR A WHILE, THE BURNPOT OVERFILLS Possible Cause: Possible Remedies: Stove or vent pipe is dirty, which restricts airfl ow Follow all cleaning procedure in the maintenance section of through the burnpot.
  • Page 24: Smoke Smell Or Soot Build-Up

    SMOKE SMELL OR SOOT BUILD-UP Because it is a wood-burning device, your Breckwell may emit a faint wood-burning odor. If this increases beyond normal or is you notice an unusual soot buildup on walls or furniture, check your exhaust system carefully for leaks. All joints should be properly sealed.
  • Page 25: Electrical Diagram

    ELECTRICAL DIAGRAM ELECTRICAL DIAGRAM POWER SUPPLY 120 VOLTS AC WHITE BLACK WHITE ORANGE ORANGE BLUE PINK YELLOW PURPLE GRAY GRAY WHITE...
  • Page 26: Replacement Parts

    REPLACEMENT PARTS REPLACEMENT PARTS Contact an Authorized Breckwell Pellet Stove Dealer to obtain any of these parts. Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. ITEM PART# Air Switch C-E-201 Air Switch Hose...