9 Installation

9.3 Connecting the sensor cable

The TS sensor cable measures the ambient temperature to optimally charge
the battery. The CTS sensor cable measures the battery temperature and
voltage to optimally charge the battery.
NOTE! When connecting, pay attention to the instructions and notes in the
sensor cable installation instructions.

9.4 Connecting the CBL control relay

14
LEAB Automotive GmbH
A potential-free changeover contact is integrated in the
ABC chargers, which switches during charging. This op-
tion can be used, for example, to implement an electrical
start interlock with 230 V connection or charge monitor-
ing.
Switching function of the changeover contact
– Pin 1 and pin 3 are connected when the charger is
switched off.
– Pin 1 and pin 2 are connected when the charger is
switched on.
Technical Data (insula-
tion)
Output to housing
Output to ground
To connect the CBL control relay, proceed as follows:
1. Plug the RJ plug connector into the connector for the
CBL relay.
ð The CBL control relay is connected.
Thorshammer 6
LEAB Automotive GmbH
Capacity (max. values)
500 V 24 V (DC): 0.5 A
120 V 120 V (AC): 0.5 A