Emerson Rosemount 928 Reference Manual page 126

Wireless gas monitor
Hide thumbs Also See for Rosemount 928:
Table of Contents

Advertisement

Operation and maintenance
February 2023
126
Supply Low: The terminal voltage is below the recommended operating range.
For battery-operated devices, replace the power module. For line powered
devices, increase the supply voltage.
SUPLY
LOW
Radio Failure: The device cannot retrieve parameter information from the radio
in the device. The device may still be operational and publishing HART
RADIO
FAILUR
Configuration Failure: Invalid configuration of the transmitter may affect critical
operation of the device. Check the extended configuration status to identify
which configuration items require connection.
CONFG
FAILUR
Configuration Warning: Invalid configuration of the transmitter may affect non-
critical operation of the device. Check the extended configuration status to
identify which configuration items require correction.
CONFG
WARN
Sensor Failure: The sensor attached to the transmitter has failed; valid readings
from that sensor are no longer possible. Check the sensor connections. Check
additional status for more detailed information about the failure source.
SNSR
FAILUR
Sensor Warning: The sensor attached to the transmitter has degraded; readings
from that sensor may not be accurate. Check the sensor and sensor wiring
connections. Check additional status for more detailed information about the
failure source.
Bandwidth Limited: The device has not received all of the requested wireless
bandwidth required to operate as configured.
Reference Manual
00809-0100-4928
data.
®
Emerson.com/Rosemount

Advertisement

Table of Contents
loading

Table of Contents