4.4.2. General Settings

The General Settings provides functions allowing items such as the Alias Name, System
Timeout value and Web Auto-logout value to be configured.
The following is an overview of the parameters contained in the General Settings section:
Item
Network
HTTP Port
System Idle
(Network
Watchdog)
Web Auto-logout
UDP
Configuration
Misc.
Alias Name
Update Settings
ECAN-240-FD (Modbus TCP to 2-port CAN FD Gateway) User Manual
Copyright © 2022 ICP DAS Co., Ltd. All Rights Reserved
The HTTP port number of the Web server function.
This parameter is used to configure the system timeout value. If
there is no activity on the network for a specific period of time,
the system will be rebooted based on the configured system
timeout value.
Timeout value range: 30 to 65535 (seconds); Disable = 0.
This parameter is used to configure the automatic logout value.
If there is no activity on the web server for a certain period of
time, the current user account will be automatically logged out.
Range: 1 to 65535 (minutes); Disable = 0.
This parameter is used to enable or disable UDP configuration
function.
This parameter is used to assign an alias for each
ECAN-240-FD device to assist with easy identification.
Click this button to save the revised settings to the ECAN-240-FD device.
All settings will take effect after rebooting the device.
Description
Version 1.0.0
E-mail: service@icpdas.com
Default
80
300
10
Enable
Modbus/C
AN FD
34
Page: