ICP DAS USA ICP CON RMV-762D-MTCP User Manual

ICP DAS USA ICP CON RMV-762D-MTCP User Manual

Hide thumbs Also See for ICP CON RMV-762D-MTCP:

Advertisement

Quick Links

RMV-762D-MTCP User Manual
Copyright © 2021 by ICP DAS Co., Ltd.
All rights are reserved.
1
RMV-762D-MTCP Module User Manual, Version 1.0.0, Jan 2021
---

Advertisement

Table of Contents
loading

Summary of Contents for ICP DAS USA ICP CON RMV-762D-MTCP

  • Page 1 RMV-762D-MTCP User Manual Copyright © 2021 by ICP DAS Co., Ltd. All rights are reserved. RMV-762D-MTCP Module User Manual, Version 1.0.0, Jan 2021...
  • Page 2 RMV-762D-MTCP User Manual Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year, starting from the date of delivery to the original purchaser. Warning ICP DAS assumes no liability for damages resulting from the use of this product. ICP DAS reserves the right to change this manual at any time without notice.
  • Page 3: Table Of Contents

    Introduction ............................4 1.1 Features ..............................5 Hardware Information ........................6 2.1 System Specifications .......................... 6 2.2 Hardware Specification ........................7 2.3 Wiring Connection ..........................8 2.4 Dimension(Units:mm) ........................9 2.5 5-Digital 7 Segment LED Display ....................10 2.6 Utility ..............................17 Appendix ..............................
  • Page 4: Introduction

    1. Introduction RMV-762D-TCP is a Modbus TCP/RTU gateway. It exchanges Modbus command from Modbus TCP/RTU master to Modbus RTU/TCP slave. Modbus TCP command can be transceived not only Ethernet port but also Wi-Fi interface. It supports Vxcomm and Point-to-Point connection. Users can choose Ethernet mode or Wi-Fi mode to do the Point-to-Point connection, which provides TCP data tunneling between two serial devices.
  • Page 5: Features

    1.1 Features General Features: Supports Point-to-Point connection applications Application Modes: Vxcomm, MB TCP/MB RTU gateway Supports static IP/DHCP Support IEEE 802.11 a/b/g for Wi-Fi mode and Limit-AP mode Support WPA and WPA2 encryption Auto control channel Easy firmware update via Ethernet Removable terminal block connector Statement of connection mode Communication Mode:...
  • Page 6: Hardware Information

    Make the Wi-Fi connection between the RMV-762D-MTCP and a Wi-Fi AP. 2. Hardware Information 2.1 System Specifications CPU Module 32-bit MCU Wi-Fi Antenna Omni-Directional 3 dBi @ 2.4 GHz 5.5 dBi @ 5 GHz Channels 2.4 GHz: CH1~11 5 GHz: CH36、40、44、48 Encryption Open/WPA/WPA2 Operation Mode...
  • Page 7: Hardware Specification

    Operating -25 ~ +75 °C Temperature Storage -30 ~ +80 °C Temperature 2.2 Hardware Specification...
  • Page 8: Wiring Connection

    2.3 Wiring Connection...
  • Page 9: Dimension(Units:mm)

    2.4 Dimension(Units:mm)
  • Page 10: 5-Digital 7 Segment Led Display

    2.5 5-Digital 7 Segment LED Display The RMV-762D-MTCP is built-in 5-Digit 7 segment LED Display. User can get the system information from the starting process. The messages are shown as VxServer, Pair-Connection Server and Pair- Connection Client types. Each type is shown as Ethernet, Limit-AP and the infrasturcture modes. Main Function Dispaly 7 segment LED Display Description...
  • Page 11 IP-2: Wi-Fi IP Address Configuration Serial Port Settings “b.01” is the baudrate 115200 bps “b.02” is the baudrate 57600 bps “b.03” is the baudrate 38400 bps “b.04” is the baudrate 19200 bps “b.04” is the baudrate 9600 bps “L.01” is the data bits 7 “L.02”...
  • Page 12 “P.02” is the data parity “ODD” “P.03” is the data parity “EVEN” “S.01” is the stop bit 1 “S.02” is the stop bit 2 RSSI Value Error Code. Please refer to the appendix. When the module is boot-up, the LED is displayed the following steps. Step 7 segment LED Display Description Initial Settings...
  • Page 13 It shows the module function 1, 2 or 3. (1) Modbus TCP Server/Modbus RTU Master (2) Modbus RTU Slave/Modbus TCP Client (3) Vxcomm Server It shows the IP address of Ethernet LAN port. For example, the IP configurations are: IP address: 192.168.255.1 Subnet Mask: 255.255.0.0 Gateway: 192.168.255.254 IP-1 (LAN IP Settings) example:...
  • Page 14 It shows the IP address of Wi-Fi interface. For example, the IP configurations are: IP address: 192.168.255.2 Subnet Mask: 255.255.0.0 Gateway: 192.168.255.254 IP-2 (Wi-Fi IP Settings) example: IP address: 192.168.255.2 Subnet Mask: 255.255.0.0 Gateway: 192.168.255.254...
  • Page 16 It shows the serial port settings. For example, the serial configurations are Baudrate: 115200 bps Data bit: 8 Stop bit: 1 Parity: None The serial configurations are Baudrate: 115200 bps Data bit: 8 Parity: None Stop bit: 1 Return the Wi-Fi RSSI value. For Example, the RSSI value is -40dbm The RSSI value is -40dbm...
  • Page 17: Utility

    2.6 Utility The RMV-762D-MTCP Utility provides an user interface for configuration. Users can configure the Wi- Fi, Ethernet, serial port and the gateway function with this convenient tool. (1) Module Connection Type the Ethernet IP address of the RMV-762D-MTCP and connect it for settings. (2) Ethernet Settings If the DHCP is disable, user can type the static IP of the LAN port to the RMV-762D-MTCP.
  • Page 18 Let the module connect to a Wi-Fi AP. SSID Set the Wi-Fi SSID of the Limit-AP mode or the Infrasturcture mode. Security ⚫ Auto Encrypt the Wi-Fi connection with WPA,WPA2 or Open. ⚫ None Made the Wi-Fi connection without any encryption. Password The password of the encryption.
  • Page 19 This IP address is available when the module is set in the “Modbus RTU Slave/Modbus TCP Client” mode. (8) Buttions Submit Click this button when the settings are complete. FW Update Users can upgrate the firmware with this button. Please refer to the following step for upgrade, Step 1) Switch to the Init mode and reboot.
  • Page 20: Appendix

    Appendix Error Code Description 00000 No Error 00001 Wi-Fi connection error in the infrastructure mode 00002 Modbus RTU communication error 00003 Modbus TCP connection loss 00004 Low RSSI ICP DAS Web Site: http://www.icpdas.com Contact Us (E-Mail): Service@icpdas.com ICP DAS Web Site: http://www.icpdas.com Contact Us (E-Mail): Service@icpdas.com Copyright @ 2014 by ICP DAS Co., Ltd.

Table of Contents