Introduction The GRP-2841M provided by ICP DAS is a gateway for Ethernet and serial port. The GRP-2841M can be used for wireless data transmission and other functions through its optional 4G / 5G / Wi-Fi communication module. With the optional GPS function, the GRP-2841M can also be used as a GPS tracking system for vehicle management or maritime system.
"192.168.255.1". It is useful when users forget the Ethernet IP. Mounting the Expansion Components GRP-2841M has two mini pcie sockets and one M.2 socket to expand the wireless communication function. Please refer to the following installation steps for installation requirements.
Installing the antenna GRP-2841M has four antenna ports, which can be used to connect 4G/5G and GPS antennas. To install the antenna, simply screw the antenna into the connector and place the antenna in the designated position. Regarding 4G or 5G antennas, there are the following options...
The "Update" page provides a firmware update function. Users can download the update file (".tarc") from the IPCDAS website, and then put it into the SD card. Please back up the configuration before updating and restore it after the update. GRP-2841M User Manual Version 1.1.0 Page:...
Page 42
[2] If the time interval between two serial data is greater than this value, the data will be divided into two network packets. If there is not enough time interval, but the data length exceeds the “Data Length”, the data is still divided into two network packets. GRP-2841M User Manual Version 1.1.0 Page:...
(2) Fill in the Ethernet IP and mask. After finishing all the settings, click "Modify". (3) If necessary, fill in "PIN Code", "APN", "User Name" and "Password". After finishing all the settings, click "Modify". GRP-2841M User Manual Version 1.1.0 Page:...
Page 51
Server IP can fill in user server IP or Google DNS server IP (8.8.8.8). If the user uses MDVPN, please make sure that the server IP does not deny the ICMP service (Ping). After finishing all the settings, click "Modify". GRP-2841M User Manual Version 1.1.0 Page:...
Page 54
Server IP can fill in user server IP or Google DNS server IP (8.8.8.8). If the user uses MDVPN, please make sure that the server IP does not deny the ICMP service (Ping). After finishing all the settings, click "Modify". GRP-2841M User Manual Version 1.1.0 Page:...
Page 58
Server IP can fill in user server IP or Google DNS server IP (8.8.8.8). If the user uses MDVPN, please make sure that the server IP does not deny the ICMP service (Ping). After finishing all the settings, press the "Modify" button. GRP-2841M User Manual Version 1.1.0 Page:...
Page 68
Server IP can fill in user server IP or Google DNS server IP (8.8.8.8). If the user uses MDVPN, please make sure that the server IP does not deny the ICMP service (Ping). After finishing all the settings, click "Modify". GRP-2841M User Manual Version 1.1.0 Page:...
Page 72
(6) Select the "Modbus Test" function, and then press the "Test" button to test the settings. If the result is successful, follow the next step. If the result failed, please check your settings or wiring. GRP-2841M User Manual Version 1.1.0 Page:...
Page 76
D. Fill in "Modbus ID" as "Modbus ID" of ET-7050, and "Modbus Name" as "ET-7050", and then press "ReadData" to get all IO data. E. Press the "Write Dos (add 1)" button to control DO. GRP-2841M User Manual Version 1.1.0 Page:...
Page 79
(3) Double-click the device node to modify the device name. (4) Now users can use OPC Client to read I/O data from NAPOPC.M2M DA Server, or use the client "Monitor" to monitor all I/O data. GRP-2841M User Manual Version 1.1.0 Page:...
Need help?
Do you have a question about the GRP-2841M and is the answer not in the manual?