Vega VEGACAP 65 Operating Instructions Manual page 32

Capacitive cable electrode for level detection
Table of Contents

Advertisement

9 Supplement
Ambient conditions
Ambient temperature on the housing
Storage and transport temperature
Process conditions
Process pressure
Ʋ Standard
Ʋ with screening tube adapter (PN1)
Process temperature VEGACAP 65 of 316L
Ʋ Insulation PTFE
Ʋ Insulation PA
Ʋ Without insulation
Process temperature (thread or flange
temperature) with temperature adapter
(option)
Process temperature VEGACAP 65 of St C22.8
Ʋ Insulation PTFE
Ʋ Insulation PA
Ʋ Without insulation
Fig. 21: Ambient temperature - Process temperature
1
Process temperature
2
Ambient temperature
3
Temperature range with temperature adapter
Dielectric constant
Electromechanical data - version IP66/IP67 and IP66/IP68 (0.2 bar)
Options of the cable entry
Ʋ Cable entry
Ʋ Cable gland
Ʋ Blind plug
Ʋ Closing cap
Wire cross-section (spring-loaded terminals)
Ʋ Massive wire, stranded wire
32
-40 ... +80 °C (-40 ... +176 °F)
-40 ... +80 °C (-40 ... +176 °F)
-1 ... +64 bar/-100 ... 6400 kPa (-14.5 ... 928 psig)
0 ... +1 bar/0 ... 100 kPa (0 ... 14.5 psig)
-50 ... +80 °C (-58 ... +176 °F)
-50 ... +80 °C (-58 ... +176 °F)
-50 ... +150 °C (-58 ... +302 °F)
-50 ... +200 °C (-58 ... +392 °F)
-20 ... +80 °C (-4 ... +176 °F)
-20 ... +80 °C (-4 ... +176 °F)
-20 ... +150 °C (-4 ... +302 °F)
2
80°C
(176°F)
40°C
(104°F)
0°C
(32°F)
-50°C
50°C
(-58°F)
(122°F)
-40°C
(-40°F)
≥ 1.5
M20 x 1.5; ½ NPT
M20 x 1.5; ½ NPT
M20 x 1.5; ½ NPT
½ NPT
0.2 ... 2.5 mm² (AWG 24 ... 14)
3
100°C
150°C
200°C
(212°F)
(302°F)
(392°F)
1
VEGACAP 65 • Two-wire

Advertisement

Table of Contents
loading

Table of Contents