Supplementary instructions
Float for oil/water detection
for VEGACAP 63
Document ID:
31595
Capacitive

Advertisement

Table of Contents
loading

Summary of Contents for Vega VEGACAP 63

  • Page 1 Supplementary instructions Float for oil/water detection for VEGACAP 63 Document ID: 31595 Capacitive...
  • Page 2: Table Of Contents

    Dimensions ....... 14 Float for oil/water detection • for VEGACAP 63...
  • Page 3: About This Document

    List The dot set in front indicates a list with no implied sequence. à Action This arrow indicates a single action. Sequence Numbers set in front indicate successive steps in a procedure. Float for oil/water detection • for VEGACAP 63...
  • Page 4: For Your Safety

    The environment management system is certified according to DIN EN ISO 14001. Please help us fulfil this obligation by observing the environmental instructions in this manual: Chapter "Storage and transport" Chapter "Disposal" Float for oil/water detection • for VEGACAP 63...
  • Page 5: Product Description

    Nut (plastic) Adapter (316L) with pin Electrode Ground electrode (screwed into the adapter) Float 3.2 Principle of operation ® Application area The float is suitable for the following plics sensors: VEGACAP 63 Float for oil/water detection • for VEGACAP 63...
  • Page 6: Storage And Transport

    Dispose of the packaging material via specialised recycling companies. Storage and transport Storage and transport temperature see chapter "Supplement - Technical data - Ambient conditions" temperature Relative humidity 20 … 85 % Float for oil/water detection • for VEGACAP 63...
  • Page 7: Mounting

    fluctuations of the measured value. Static charges There is a danger of static charging on the plastic floating body. Avoid friction No dry cleaning Do not mount in areas with flowing, non-conductive products Float for oil/water detection • for VEGACAP 63...
  • Page 8: Connect The Sensor

    For this reason, use a light, flexible connection cable and fasten the cable on a cable holder. 5.2 Connection procedure The electrical connection is described in the operating instructions of the sensor. Float for oil/water detection • for VEGACAP 63...
  • Page 9: Setup

    Set potentiometer (1) to 0. The relay control lamp (2) lights. Turn the potentiometer (1) slowly clockwise until the relay control lamp (2) extinguishes. Turn the potentiometer (1) very slowly anticlockwise until the relay control lamp (2) lights. Float for oil/water detection • for VEGACAP 63...
  • Page 10 Fig. 5: Switching status of the measuring system No liquid present Water Oil layer on water Liquid level water Liquid level oil > 4 mm (> 0.157 in) Float for oil/water detection • for VEGACAP 63...
  • Page 11: Maintenance

    If a repair of the instrument is necessary, please proceed as follows: You can download a return form (23 KB) from our Internet homepage www.vega.com under: "Downloads - Forms and certificates - Repair form". By doing this you help us carry out the repair quickly and without having to call back for needed information.
  • Page 12: Dismounting

    (e.g. in Germany according to electronic scrap ordinance). Materials: see chapter "Technical data" If you have no way to dispose of the old instrument properly, please contact us concerning return and disposal. Float for oil/water detection • for VEGACAP 63...
  • Page 13: Supplement

    The floating body can be used in Ex area zone 1 (ATEX II 2G). There is a danger of static charging on the plastic floating body. Avoid friction No dry cleaning Do not mount in areas with flowing, non-conductive products Float for oil/water detection • for VEGACAP 63...
  • Page 14: Dimensions

    ø 25 mm (0.98") ø 25 mm (0.98") Fig. 6: Measuring system for oil/water detection with VEGACAP 63 point level sensor Order length of the VEGACAP 63 level sensor (L = 160 mm) Float for oil/water detection • for VEGACAP 63...
  • Page 15: Float For Oil/Water Detection • For Vegacap

    9 Supplement Float for oil/water detection • for VEGACAP 63...
  • Page 16 All statements concerning scope of delivery, application, practical use and operating conditions of the sensors and processing systems correspond to the information avail- able at the time of printing. © VEGA Grieshaber KG, Schiltach/Germany 2010 31595-EN-100604 Subject to change without prior notice...