PRESYS
⏐ Instruments
SOFT - shows software version.
PASS - allows the user to enable or disable the password system for accessing
the configuration mode. The password system may be chosen as key sequence, a value
(number chosen by the user and number 2030) or both. The correct key sequence is
obtained by pressing the UP, DOWN and ENTER keys in this order.
INDIC - is an option for the visualization of the measured variables on the display.
It allows the user to view the values of channels 1 and 2 only by pressing the UP and
DOWN keys, or it sets the instrument to change automatically the indication of the
measured variable of each channel. In the former case choose NO for TWO option, and
for the latter case, choose YES (automatic scan mode) for TWO option and provide the
exhibition times (given in seconds) for viewing each channel.
The table below refers to the ranges of the parameters shown in Figure 9.
Mnemonic
TAG
SOFT
VALUE
TIME1
TIME2
Fig. 9 - GENERAL level options
Parameter
instrument
identification
software version
user password
channel 1
exhibition time
channel 2
exhibition time
DMY-2030-F / DMY-2030-F Light
Range
_____________
_____________
-9999 to 30000
1 to 3000
1 to 3000
Factory
Units
Value
__________
F2030
__________
1.20
__________
0
5
seconds
1
seconds
Operation
Page 15