TE-25N / TE-35N / TE-50N
Technical Manual
EM0434-00

Advertisement

Table of Contents
loading

Summary of Contents for Presys TE-25N

  • Page 1 Dry Block Calibrators TE-25N / TE-35N / TE-50N Technical Manual EM0434-00...
  • Page 2 The warranty conditions are available in our sites: www.presys.com.br/warranty...
  • Page 3: Table Of Contents

    PRESYS  Instrumentos e Sistemas TE-25N / TE-35N / TE-50N Table of Contents 1.0 - Introduction ........................ 3 1.1 - Technical Specifications ................... 5 1.2 - Order Code ....................... 6 1.3 - Acessories ........................ 7 2.0 - Calibrator Operation ....................8 2.1 - Menu IN ........................
  • Page 4: Introduction

    RTD and TC sensors, and even measures mA. The TE-25N, T E-35N and t he T E-50N models generates t emperatures f rom - 25 ºC to 155 ºC, -35 ºC to 155°C and -50ºC to 155°C, respectively.
  • Page 5 The TE-25N, TE-35N and TE-50N models has also many other features, such as: • The electric signal calibrator is independent from the dry block function.
  • Page 6: Technical Specifications

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 1.1 - Technical Specifications TE-25N TE-35N TE-50N Operating Range Ambient Temperature: -25 ºC to 155 ºC -35 ºC to 155 ºC -50 ºC to 155 ºC up to 23 °C Accuracy with Internal ...
  • Page 7: Order Code

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 1.1.1 - Input Technical Specifications Resolution Accuracy Remarks Input Ranges 0.01 Ω ± 0.005 % FS Probe Ext.¹ 0 to 400 0.01 ºC / 0.01 ºF ± 0.05 ºC / ± 0.1 ºF IEC-60751 Probe Ext.¹...
  • Page 8: Acessories

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 1.3 - Acessories • Inserts: Description Holes Order Code IN01 1 x 3/4’’ 06.04.0011-00 IN02 1 x 1/2’’ 06.04.0012-00 IN03 1 x 6,0 mm and 3 x 1/4’’ 06.04.0013-00 IN04 3 x 6,0 mm and 1 x 1/4’’...
  • Page 9: Calibrator Operation

    EXEC: The calibrator enters the manual or programmable operating mode. CONF: Accesses the calibrator configuration options. More details in item 2.2 - Menu CONF. TE-25N/TE-35N/TE-50N CAL: This option accesses the calibrator adjust functions, protected by password. More details in section 6 - Calibration.
  • Page 10: Menu In

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 2.1 - Menu IN  mV, mA, SW: selects milivolt, miliampere or switch input, respectively. OHM: selects ohms input. Following, choose from the menu the wiring 2, 3 or 4 wire.
  • Page 11: Input Connectons Diagrams

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 2.1.1 - Input Connectons Diagrams Page 10...
  • Page 12: Menu Conf

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 2.2 - Menu CONF  CF: Selects the temperature unit between ºC or ºF. The ITS-90 or IPTS-68 temperature scales are selected for both the thermo-element and for the internal block reference readings purpose.
  • Page 13 PRESYS  Instruments TE -25N / TE-35N / TE-50N  DEFAULT DEC_PRB: Selects the number of decimals of the block temperature and the set point value. The default number is 2.  SP: Enables the calibrator Programmable Operating Mode, and allows the configuration of programmed values.
  • Page 14 SCALE HIGH: 100.0 # SCALE LOW: 0.0 # MEM: The TE-25N/TE-35N/TE-50N calibrator allows many special programs and functions that can be of frequent use. In situations like this, it would be useful to store the current configuration in memory in order to save time. Up to 8 configurations can be stored in memory.
  • Page 15: Manual Operating Mode

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 2.3 - Manual Operating Mode The display shows the selected temperature There are 4 ways in which the information are shown, covering the calibrator input value (IN), the block temperature (PROB) and the temperature set point (SET). The key ...
  • Page 16: Automatic Operating Mode

    PRESYS  Instruments TE -25N / TE-35N / TE-50N The countdown of the stabilization time is only started when the block temperature reaches the programmed temperature and stabilizes withing a range of aproximately 0.05 ºC. At this time the buzzer beeps, in case it is configured to YES.
  • Page 17 TAGMAN with the key ENTER. The option ADDRESS selects the communication address of the TE-25N/TE- 35N/TE-50N calibrator. The communication protocol used is ModBus - RTU, with no parity and baud rate of 9600. The calibrator communication with the computer can use RS-232 or RS- 485, for network option, according to the communication interface used.
  • Page 18: Recommendations As Regards Accuracy Of Measurements

    In t he s pecific c ase of g enerating n egative temperature wit h the TE-25N/TE- •...
  • Page 19: Recommendantions To Other Types Of Insert

    PRESYS  Instruments TE -25N / TE-35N / TE-50N In this case, the dry block is only used as a heat generator, not as a standard temperature calibrator. The user can use the fact that the dry block stability value is much lower than its accuracy value.
  • Page 20: Calibration

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 6.0 - Calibration Warning: Enter the following options only after understanding them completely. Otherwise, it may be necessary to return the instrument to the factory for recalibration! Select CAL option from the menu and press the ENTER key. You should then enter the password (PASSWORD) 9875 to access the calibration menu.
  • Page 21 PRESYS  Instruments TE -25N / TE-35N / TE-50N a) Application of mV signal: For the calibration below, leave terminals RTD3 (+) and RTD4 (+) short-circuited. mV Signal Terminals point point V_OHM3 RTD3(+) e mV(-) 90,000 mV 120,000 mV V_OHM4...
  • Page 22: Instructions For Hardware Maintenance

    PRESYS  Instruments TE -25N / TE-35N / TE-50N 7.0 - Instructions for Hardware Maintenance There are no parts or components in the temperature calibrator that can be repaired by the user. Only the 6Amp fuse, placed within the socket on the rear can be replaced by the user.
  • Page 23: Tiny Steel Balls (Optional), Recommendations Of Use

    9 .0 - Tiny Steel Balls (Optional), Recommendations of Use As an optional, the dry block calibrators offers a plastic container with tiny steel balls and a cup-like insert. This item are exclusive accessories of PRESYS dry block calibrators, which is proper for being filled with the tiny balls.
  • Page 24 Presys www.presys.com.br...