Enerzone SOLUTION 3.3 Owner's Manual page 19

Hide thumbs Also See for SOLUTION 3.3:
Table of Contents

Advertisement

3.1.3
With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada
A
14 ½" (368 mm)
B
15" (381 mm)
C
12" (305 mm)
L
70" (1778 mm)
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
8" (203 mm)
B
14" (356 mm)
C
10" (254 mm)
L
70" (1778 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
1
WITH SINGLE WALL PIPE CONNECTOR
Canada
D
18" (457 mm)
E
23 ¾" (603 mm)
F
21 ¾" (552 mm)
1
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances above
mentioned.
Installation and Operation Requirements - Solution 3.3
USA
14 ½" (368 mm)
15" (381 mm)
12" (305 mm)
70" (1778 mm)
USA
8" (203 mm)
14" (356 mm)
10" (254 mm)
70" (1778 mm)
FROM PIPE CONNECTOR
USA
18" (457 mm)
23 ¾" (603 mm)
21 ¾" (552 mm)
Ve
Ho
DISTANCES
FROM PIPE CONNECTOR
1
WITH DOUBLE WALL PIPE CONNECTOR
Canada
11 ½" (292 mm)
D
E
22 ¾" (578 mm)
F
19 ¾" (502 mm)
L
USA
11 ½" (292 mm)
22 ¾" (578 mm)
19 ¾" (502 mm)
Page 19