Enerzone SOLUTION 3.3 Owner's Manual page 13

Hide thumbs Also See for SOLUTION 3.3:
Table of Contents

Advertisement

X
X
Figure 14: Position of the bottom
Figure 15: Position of the top pieces
pieces (Low burn)
(Low burn)
Let the door ajar at 90° until the flames roll on top of the fuel (between 2:00 and 4:00 minutes)
and then close the door with the primary air control open. See picture below for rolling flame:
X
Close the primary air control by small increments (ex: 1/16 of an inch), from ½'' to fully closed,
between 4 and 15 minutes after the loading period. Before closing further, make sure the flame
intensity is increasing or stable. Close the air control completely. Turn ON the blower at minimum
speed after 30 minutes.
2.4.4
Medium burn rate
After the high fire, if there is visible yellow flame, close the air control. When the charcoal bed
weight is between 14 and 17% of the medium fire load weight, turn off the blower, open the
door, stir the coals slightly, just enough to have a level plane coal bed, and let the door remain
slightly open for 1 minute before loading the medium burn test fuel.
For the loading, place the first two logs at the back of the firebox, facing east-west, one on top
of the other. Leave approximately 3 inches of air space between the rear firebrick and the first
log. See Figures 16 and 17 for an example load for maximum burn rate inside the combustion
chamber (illustrative only). Then, place 2 logs in the middle and 2 logs in front of the combustion
chamber, one on top of the other (6 logs in total). Leave one inch between log columns.
For optimal medium fire load,take small size fuel pieces (between 2- and 3-inches cross section
dimensions approximately) in the back of the firebox and use medium to large size fuel pieces
(3.5 to 4.5 inches of cross section dimensions approximately) in front of the firebox.
Installation and Operation Requirements - Solution 3.3
Page 13