3.1.2
With Airmate
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
A
6" (152mm)
B
12" (305 mm)
C
8" (203 mm)
It is possible to install a single wall pipe. For clearances, refer to the dimensions in 3.1.
A
B
E
CAN
48"
122 cm
Note that to reduce the clearances of an appliance using a single wall pipe connector, the use of a heat shield certified with the single wall pipe
1
connector to be used as close as 6" from combustible materials must be used. Only in this case, the same clearances as a certified double wall
pipe connector can be used.
Page 18
USA
6" (152mm)
12" (305 mm)
8" (203 mm)
D
48"
US
Flush
36"
92 cm
DISTANCES
FROM DOUBLE WALL PIPE
1
CONNECTOR
Canada
D
9 ½" (241 mm)
E
20 ¾" (527 mm)
F
17 ¾" (451 mm)
F
F
Installation and Operation Requirements - Solution 3.3
USA
9 ½" (241 mm)
20 ¾" (527 mm)
17 ¾" (451 mm)
C