Appendix 5: Parameter Programming Examples

The following examples show you how to program parameters by scanning programming barcodes.
a. Program the Decode Session Timeout
Example: Set the decode session timeout to 1500ms
1.
Scan the Enter Setup barcode.
Scan the Decode Session Timeout barcode. (See the "Decode Session Timeout" section in
2.
Chapter 3)
Scan the numeric barcodes "1", "5", "0" and "0" from Appendix 6.
3.
4.
Scan the Save barcode from Appendix 7.
5.
Scan the Exit Setup barcode. (If you still need to program other parameter/feature, skip this step.)
b. Program the Timeout between Decodes (Same Barcode)
Example: Set the timeout between decodes (same barcode) to 1000ms
1.
Scan the Enter Setup barcode.
Scan the Timeout between Decodes (Same Barcode) barcode. (See the "Timeout between
2.
Decodes (Same Barcode)" section in Chapter 3)
Scan the numeric barcodes "1", "0", "0" and "0" from Appendix 6.
3.
4.
Scan the Save barcode from Appendix 7.
5.
Scan the Exit Setup barcode. (If you still need to program other parameter/feature, skip this step.)
c. Program the Threshold Value of Illumination Change
Example: Set the threshold value of illumination change to 4
1.
Scan the Enter Setup barcode.
Scan the Threshold Value of Illumination Change barcode. (See the "Sensitivity" section in
2.
Chapter 3)
Scan the numeric barcode "4" from Appendix 6.
3.
4.
Scan the Save barcode from Appendix 7.
5.
Scan the Exit Setup barcode. (If you still need to program other parameter/feature, skip this step.)