Beater Rotation
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
To correct the rotation on a three-phase unit,
interchange any two incoming power supply lines at
unit's main terminal block only.
To correct rotation on a single-phase unit, change
the leads inside the beater motor. (Follow the
diagram printed on the motor.)
Electrical connections are made directly to the
terminal block provided in the main control box
located under the upper left side panel on the
countertop unit, or behind the service panel on the
console units.
It is recommended that beater rotation be performed
by an authorized Taylor service technician.
Refrigerant
In consideration of our environment, Taylor
uses only HFC refrigerants. The HFC refrigerant
used in this unit is R404A. This refrigerant is
generally considered non-toxic and non-flammable,
with an Ozone Depleting Potential (ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Model 793
Use only R404A refrigerant that conforms
to the AHRI standard 700 specification. The use of
any other refrigerant may expose users and
operators to unexpected safety hazards.
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe,
apply ice packs and contact a physician
immediately.
Taylor reminds technicians to be aware of
and in compliance with local government laws
regarding refrigerant recovery, recycling, and
reclaiming systems. For information regarding
applicable local laws, please contact your local
authorized Taylor distributor.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely
moisture absorbent. When opening a refrigeration
system, the maximum time the system is open must
not exceed 15 minutes. Cap all open tubing to
prevent humid air or water from being absorbed by
the oil.
3
131021