NOTE: The serial number is the content required by some applications that must be
written in a certain area for every chip. This information includes the product
sequence number and the MAC address.
To have the software generate the serial number, select Enable AutoIncrement.
1. Enter the automatic start buffer address in the Start Addr field.
2. Enter the automatic end buffer address in the End Addr field.
3. Enter an increment value less than 10 in the Inc. Step field.
4. The AutoInc Format defines the start value and the overflow value. The
overflow value is the number at which the increment ceases and carries to the
next address, which becomes the new start value.
Select Binary to set the start value as 0 and the overflow value as 256.
Select ASCII Decimal to set the start value as 30 (hexadecimal
representation of 0) and the overflow value as 39+1 (the hexadecimal
representation of 9).
Select ASCII Hex to set the start value as 30 (hexadecimal
representation of 0) and the overflow value as 46+1 (the hexadecimal
representation of a number greater than F, where 9+1=A).
To define the increase of the serial number, select User's Definition. You must be
authorized to use this function. If so, you can change the data as desired in the 4K
byte range.
4.4.4 Count
The Count view of the Operation Option screen is illustrated below. This screen
allows you to change the default setting regarding the statistical work of the
programming status. In the default case, it is only effective for the function
program".