Appendix
Function group
CHECK
P
Function group
RELAY
R
Function group
SERVICE
S
F unction group
SERVICE 2
E
Function group
INTERFACE
I
98
SCS alarm
SCS alarm
Measuring sensor
Reference sensor
(if A2=sym)
off
; on
P1
off
; on
P2
Limit contactor
configuration
Neutr =
R2 (6)
neutralisation controller
(with Rel1 and Rel2
and A1 = pH only)
Clean =
R2 (5)
Chemoclean
(with Rel3 only)
Timer
R2 (4)
PID controller
R2 (3)
LC °C =
Limit contactor T
R2 (2)
LC PV =
Select contact to be
Limit contactor
configured
pH/Redox
Rel1
; Rel2; Rel3; Rel4;
R2 (1)
R1
Select language
Hold configuration
s+c=during setup and
ENG
; GER
calibration
ITA; FRA
CAL=during calibration
ESP; NEL
Setup=during setup
none=no hold
S2
S1
Software version
Select module
SW version
Rel = relay
E1(4)
E141
Software version
MainB =
E1(3)
SW version
mainboard
E131
Software version
Trans =
SW version
transmitter
E1(2)
E121
Software version
Contr = controller
SW version
E1(1)
E111
Enter address
Tag is displayed
HART: ...15
0
or PROFIBUS 1...
126
@@@@@@@@
I1
I2
SCS alarm threshold
Leakage current is
displayed
(ISFET sensors only)
50 k
W
P3
1.5...50 kW
P4
0.0 ... 9.9 mA
Function
R2 (6)
Set point 1 (or 2)
switch off or on
6.00 pH
-2.00...16.00 pH
off
; on
R261
R262
Select start pulse
Function
R2 (5)
int = internal
;
switch off or on
ext = external;
i+ext = internal +external;
off
; on
i+stp = internal,
suppressed by ext
R251
R252
Function
R2 (4)
Set rinse time
switch off or on
30 s
off
; on
0...999 s
R241
R242
Enter set point
Function
R2 (3)
switch off or on
pH 16.00
; -2.00...16.00 pH
1500 mV
; -1500...1500 mV
off
; on; basic; PID+B
100.0 %
; 0...100.0 %
R231
R232
Function
R2 (2)
Enter switch-on
switch off or on
temperature
off
; on
150.0 °C
-50.0...+150.0°C
R221
R222
Select contact switch-on
Function
R2 (1)
point
switch off or on
16.00 pH
; -2.00...16.00 pH
off
; on
1500 mV
; -1500...1500 mV
100.0 %
; 0...100.0 %
R211
R212
Manual hold
Enter hold
dwell period
off
; on
10 s
0...999 s
S3
S4
Serial number
Hardware version
is displayed
HW version
E142
E143
Serial number
Hardware version
is displayed
HW version
E132
E133
Serial number
Hardware version
is displayed
HW version
E122
E123
Serial number
Hardware version
is displayed
HW version
E112
E113
OPM223/253
Select process
Alarm delay
monitoring
Off
; Low; High;
0 min (s)
P5
LoHi; Lo!; Hi!; LoHi!
0 ... 2000 min (s)
P6
Enter control
Enter integral action time
Tn (0.0 = no I component)
gain Kp1 (or Kp2)
0.0 min
1.00
0.0...999.9 min
0.01...20.00
R263
R264
Enter pre-rinse time
Enter cleaning time
30 s
10 s
0...999 s
0...999 s
R254
R253
Set pause time
Set minimum pause
time
360 min
1...7200 min
120 min
1...3600 min
R243
R244
Enter control
Enter integral action time
gain Kp
Tn (0.0 = no I component)
1.00
0.0 min
0.01...20.00
0.0...999.9 min
R233
R234
Enter switch-off
Enter pick-up delay
temperature
150.0 °C
0 s
-50.0...+150.0°C
0...2000 s
R223
R224
Select contact switch-off
Enter pick-up delay
point
pH 16.00
; pH -2.00...16.00
0 s
1500 mV
; -1500...1500 mV
0...2000 s
100.0 %
; 0...100.0 %
R213
R214
Enter release code
Enter release code for
for SW upgrade
SW upgrade
(Plus package)
ChemoClean
0000
0000
0000...9999
0000...9999
S5
S6
Module name
is displayed
E144
Module name
is displayed
E134
Module name
is displayed
E124
Module name
is displayed
E114