5

WIRING METHOD

5-1

POSITION AND RATING OF TERMINALS

Power input
1
(no polarity)
2
Current consumption: PXB- 50F: 9mA
Tamper output
10
11
5-2

WIRING DISTANCE BETWEEN SENSOR AND POWER SUPPLY

Part No.
Size of
electrical cable used
Up to 2,700ft. ( 823m)
AWG 20 (Dia,0.8mm)
Up to 4,200ft. (1,280m)
AWG 18 (Dia,1.0mm)
AWG 17 (Dia,1.1mm)
Up to 5,100ft. (1,550m)
AWG 16 (Dia,1.25mm)
Up to 6,600ft. (2,000m)
Up to 8,300ft. (2,500m)
AWG 15 (Dia,1.4mm)
AWG 14 (Dia,1.6mm)
Up to 10,500ft. (3,200m)
When 2 or more units are connected, the wiring distance is calculated as follows: [Above value/number of units]
5-3

WIRING DISTRIBUTION DIAGRAM (WIRING DIAGRAM)

Basic connections
Transmitter
Receiver
For environmental output, tamper output
Transmitter
Receiver
[Precautions for Installation]
(1) Signal output for the upper and lower levels of the receiver cannot be output separately.
(2) For outdoor wiring installation, carry out pipe laying work whenever possible.
(3) Never use overhead wiring.
<Transmitter>
12 to 30V DC
PXB-100F:11mA
PXB-200F:13mA
30V (AC/DC) 0.1A
No-voltage contact: b contact
Built-in contact protection resistance
PXB-50F
12V DC
24V DC
Up to 19,000ft. ( 5,790m)
Up to 29,500ft. ( 8,990m)
Up to 36,000ft. (11,000m)
Up to 46,000ft. (14,000m)
Up to 58,000ft. (17,700m)
Up to 76,000ft. (23,200m)
When multiple sensor units are connected
to the same circuit
Power supply
(12 V DC)
Alarm signal
(b contact)
(Controller)
Transmitter
Receiver
Alarm signal (b contact)
Tamper signal (b contact)
Environment signal (b contact)
1
2
3
4
5
6
7
8
9
10
11
PXB-100F
12V DC
Up to 2,500ft. ( 750m)
Up to 17,000ft. ( 5,200m)
Up to 3,800ft. (1,160m)
Up to 27,500ft. ( 8,380m)
Up to 4,800ft. (1,460m)
Up to 33,000ft. (10,000m)
Up to 6,200ft. (1,890m)
Up to 43,000ft. (13,100m)
Up to 7,800ft. (2,380m)
Up to 53,000ft. (16,000m)
Up to 10,000ft. (3,000m)
Up to 71,000ft. (21,600m)
Power supply
(12 V DC)
Alarm signal
(b contact)
(Controller)
Receiver
Transmitter
Transmitter
Power supply (12 V DC)
(Controller)
<Receiver>
Power input
12 to 30V DC
(no polarity)
Current consumption: PXB- 50F: 19mA
PXB-100F: 19mA
COM
PXB-200F: 19mA
Alarm output
30V (AC/DC) 0.25A (Resistance load)
No-voltage relay contact: c contact
NC
Built-in contact protection resistance
NO
COM
Environmental output
30V (AC/DC) 0.25A (Resistance load)
No-voltage relay contact: c contact
NC
Built-in contact protection resistance
NO
VACANT
Tamper output
30V (AC/DC) 0.1A
No-voltage contact: b contact
Built-in contact protection resistance
PXB-200F
24V DC
12V DC
Up to 2,300ft. ( 700m)
Up to 3,700ft. (1,130m)
Up to 4,500ft. (1,370m)
Up to 5,800ft. (1,770m)
Up to 7,300ft. (2,350m)
Up to 9,500ft. (2,900m)
When multiple sensor units are connected
to separate circuits
Receiver
Receiver
Transmitter
24V DC
Up to 16,000ft. ( 4,880m)
Up to 25,000ft. ( 7,500m)
Up to 31,000ft. ( 9,500m)
Up to 40,000ft. (12,000m)
Up to 51,000ft. (15,500m)
Up to 66,000ft. (20,000m)
Power supply
(12 V DC)
Alarm signal 1
(b contact)
Alarm signal 2
(b contact)
(Controller)