10
SPECIFICATIONS
Model
Detection system
Infrared beam
Protection distance
Max. arrival distance
Response time
Power supply
Current consumption
Alarm output
Environmental output
Tamper output
Alarm LED
Attenuation LED
Ambient temperature range
Beam adjustment
Functions
Mounting positions
IP rating
Wiring
Weight
Appearance
PXB-50F
Near infrared pulsed beam interruption system
(TR-RE 4 beam simultaneous interruption)
Double modulation pulsed beam by LED
Outdoor 165' (50 m) or less
Outdoor 330' (100 m) or less Outdoor 660' (200 m) or less
1650' (500 m)
0.05 sec. to 0.7 sec. (Variable at pot)
28 mA or less
Dry contact relay output form C
Contact action : Interruption time (Min.2sec.)
Contact capacity : 30V (AC/DC) 0.25A (resistive load)
Dry contact relay output form C
Action : Activated when weather condition gets worse
Contact capacity : 30V (AC/DC) 0.25A (resistive load)
Action : Activated when cover is detached
Contact capacity : 30V (AC/DC) 0.1A (resistive load)
Red LED (Receiver)
Red LED (Receiver)
–31°F to +151°F (–35°C to +66°C)
Horizontal: ±90°, Vertical: ±20°
Tone indicator, Environmental module, Monitor jack, Tamper
Response time adjustment, Upper/Lower beam switch, Wireless checker
Automatic gain control
Transmitter : 52.5oz (1500g)
PXB-100F
3300' (1000 m)
12 to 30V DC (Non-polarity)
30 mA or less
Protective resistor
Protective resistor
Dry contact relay (N.C.)
Protective resistor
ON : when an alarm is initiated
ON : when beam is attenuated
Outdoor, Indoor
65
Terminals
Receiver : 54.3oz (1550g)
Resin (wine red)
PXB-200F
6600' (2000 m)
32 mA or less