HR6S-AB
Safety Relay Module
PLc achieved with Category 1 configuration
• With a variety of common input devices, the HR6S-AB can monitor two-
hand control devices (IIIA) that are required to comply with ISO 13851.
• Suitable for use as a self-holding circuit for selecting a wide variety of
start functions for low-risk machines.
• Output cannot be expanded using expansion modules.
HR6S-AB
Terminal
Part No.
Push-in terminal
HR6S-AB1C
HR6S-AB1P
Screw terminal
• One sealing strip (see page 28) is included with each product.
Overview of Application Functions
Monitoring of Emergency
Stop circuits as per ISO
13850 and IEC 60204-1,
stop category 0
Monitoring of guards as
per ISO 14119/14120
with interlock switches
Safety-Related Outputs
Number of relay contacts, changeover (Normally Closed to
Normally Open), instantaneous
Maximum short circuit current IK
Maximum continuous current, Normally Open relay contacts
Maximum continuous current, Normally Closed relay contacts 3 A
Maximum total thermal current ∑I
THERM
Minimum current
Utilization category as per UL 60947-5-1
Utilization category as per IEC 60947-4-1 and IEC 60947-5-1
Maximum current, normally open relay contacts
Maximum current, normally closed relay contacts
External fusing
Additional Non-Safety-Related Outputs
Output voltage
Maximum current
Synchronization Times
The synchronization times for the synchronization of safety-related
inputs depend on the application function. (See page
Selector and Input Device Connection Example.)
8
Package Quantity: 1
Supply Voltage
24V AC/DC
24V AC/DC
Monitoring of two-hand
control devices, type III A
as per ISO 13851
Monitoring of guards as
per ISO 14119/14120
with coded magnetic
switches
Data Functional Safety
1
1 kA
3 A
3 A
10 mA
D300 and R300
AC-1: 250 V
AC-15: 250 V
DC-1: 24 V
DC-13: 24 V
AC-1: 5 A
AC-15: 3 A
DC-1: 5 A
DC-13: 2 A
AC-1: 3 A
AC-15: 1 A
DC-1: 3 A
DC-13: 1 A
6 A, category gG
24V DC
20 mA
*1) According to ISO 13849-1 Annex K
9
Function Mode
Monitoring of proximity
switches
Monitoring of electro-sensitive
protective equipment such as
type 4 light curtains as per
IEC 61496-1
Defined safe state
Maximum Performance Level (PL), Category
(as per ISO 13849-1:2015)
Maximum Safety Integrity Level (SIL)
(as per IEC 61508-1:2010)
Safety Integrity Level Claim Limit (SILCL)
(as per IEC 62061:2005+AMD1:2012
+AMD2:2015)
Type (as per IEC 61508-2)
Hardware Fault Tolerance
(HFT) (as per IEC 61508 and IEC 62061)
Stop Category for Emergency Stops
(as per ISO 13850 and IEC 60204-1)
Lifetime in years at an ambient temperature of 55 °C (131 °F) 20
Safe Failure Fraction (SFF)
(as per IEC 61508 and IEC 62061)
Probability of Dangerous Failure per hour (PFH
(as per IEC 61508 and ISO 13849-1)
Mean Time To Dangerous Failure (MTTF
) in years
D
(as per ISO 13849-1)
Average Diagnostic Coverage (DC
)
avg
(none as per ISO 13849-1)
DC-13
Maximum number of cycles
over lifetime
AC-15
For other specifications (common to all models), see page 27.
• See website for details on
TÜV NORD Systems
GmbH & Co.KG
approvals and standards.
Monitoring of RFID
sensors
Safety-related outputs are
de-energized
Normally Open: open
Normally Closed: closed
PLc, Category 1
1
1
B
0
0
>60 %
) in 1/h
1175.6 x 10-9
D
91 (*1)
24V DC 2 A: 50000