7.System Settings
Settings of the MEASURE function
Item
Acquire function
Data function
Integrated data
display
Settings of the SEQUENCE function
Item
Program
Program selection
Settings of the SYSTEM function
Item
Remote sensing
Panel settings at startup (Power On)
Watchdog protection function
Set time for watchdog protection function (Delay)
Screen saver
Screen saver startup time (Delay)
Key lock level
Beep sound
I/O direction of DIGITAL2 signal
Time zone
For details on the factory default settings and reset settings for the interface, see "List of set-
ting items"
PLZ-5W
Number of times measurement values are to be
acquired (count)
Delay
Measurement interval function (Interval)
Measurement interval time (Interval Time)
Trigger source
Sense aperture
Integrated data recording period (Integral Gate)
Resetting of integrated data before start of
recording (Reset)
Elapsed time
Capacity
Energy
In case of invalid operation (Key)
In case of protection activation
In case of SCPI error
(p.88)
in " Displaying/Changing the Interface Settings".
Factory Default Settings and Reset Settings
Factory default
Immediate
Load On
Factory default
No program
No selection
Factory default
Resume
Reset
1
0 s
Disable
0.1 s
0.1 s
Auto
Disable
–
Disable
–
Disable
–
Reset
–
Reset
Disable
–
–
Disable
–
60 s
–
Disable
–
60 s
–
High
–
Enable
–
Enable
–
Enable
–
Input
–
UTC
–
93