Kikusui PLZ-5W Series User Manual page 26

Electronic load
Hide thumbs Also See for PLZ-5W Series:
Table of Contents

Advertisement

Setting the Operation Mode
26
Example: Setting I-V characteristics
You can smoothly set the I-V characteristics by first setting the
row with the maximum voltage, and then proceeding to set the
other values in decreasing order. As an example, let's set the
I-V characteristics while referring to the table on the right.
1
Press •Level and then Table.
The I-V characteristics editing screen appears.
2
Press Count, use the numeric keypad or the rotary knob to enter "6",
and then press ENTER.
The voltage and current value rows are added.
3
Use the rotary knob to select the 6th row.
4
Use the → key to select the Current row, and then press Table(•Edit).
5
Use the numeric keypad or the rotary knob to enter "0.8", and then press
ENTER.
6
Use the rotary knob to select the 5th row
7
Use the ← key to select the Voltage row, and then press Table(•Edit).
8
Use the numeric keypad or the rotary knob to enter "4.5", and then press
ENTER.
9
Use the → key to select the Current row, and then press Table(•Edit).
10
Use the numeric keypad or the rotary knob to enter "0.8", and then press
ENTER.
11
In the same manner, set the voltage and current values on the 4th, 3rd,
and 2nd rows.
The I-V characteristics are now set.
2.Basic Functions
Example of settings
Voltage [V]
Current [A]
0
0
3.2
0.02
4.0
0.1
4.3
0.3
157.5
0.8
PLZ-5W

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plz205wPlz405wPlz1205wPlz2405wb

Table of Contents