4.4.8 TEMP 1 & TEMP 2 (POOL OR SPA ONLY)
EQUIPMENT ON/OFF
Select TEMP 1 to set the system's
priority temperature.
• TEMP 1 must be higher than
TEMP 2, and must be set first.
• When TEMP 1 is enabled, it will
override TEMP 2.
Select Temp 2 to set the system's
maintenance (low) temperature.
• If Temp 2 is ON and Temp 1 is
activated, Temp 2 will turn OFF
and ENABLED will flash.
• Temp 2 reactivates when Temp1
turns OFF.
4.5 LIGHTING
4.5.1 LIGHT COLORS (POOL LIGHT/SPA LIGHT)
EQUIPMENT ON/OFF
Select to set and turn on the color
of a pool or spa color light.
• Selecting a different color when
the light is already ON will cause
the system to cycle from Alpine
White to the selected color.
• The last color chosen will be the
default when turning on a pool
or spa light manually through
the OneTouch control panel or a
program.
• Press the Back key to accept the
last selected light color. After 15
seconds without pressing any
keys, the most recently selected
light color will be accepted again.
ENGLISH
Filter Pump
Temp 1
Temp 2
Solar Heat
Filter Pump
Temp 1
Temp 2
Solar Heat
Filter Pump
Spa
Solar Heat
Pool Light
Aux 2
AquaLink
RS OneTouch™ | Owner's Manual
®
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
Temp 1
Enabled
Set To
80°F
Temp 2
Enabled
Set To
80°F
OFF
OFF
OFF
OFF
OFF
Pool Light
Will Turn Off
In 5 Seconds. If
You Want To
Change The
Color Press
Select Now.
Temp 1
must be set
higher than
Temp 2
press ANY key
to continue.
Filter Pump
ON
Temp 1
ON
ON
Temp 2
OFF
Solar Heat
Aux 1
OFF
OFF
Aux 2
OFF
Aux 3
Aux 4
OFF
OFF
Aux 5
Aux 6
OFF
Aux 7
OFF
All Off
Filter Pump
OFF
OFF
Spa
OFF
Solar Heat
Pool Light
ON
OFF
Aux 2
Set Color
Alpine White
Sky Blue
Cobalt Blue
Caribbean Blu
Color Splash
Please
Wait . . .
Cycling To
Chosen
Color
Need help?