3-13. Data initialization method
There are three ways to initialize data:
A:On the Home screen, press and hold the key to initialize the data other than the following to the factory default settings.
P17-N04 、 P18 、 P19 、 P25 、 P26 、 P32 、 P33 、 P58 、 P59 、 P70 、 P74 、 P75 、 P92 、 P129 、 P144 、 P145 、
P177 ~ P200 、 P235 ~ P242
Normally, memory switches other than those listed above are initialized to the factory default settings. However, memory
switches with default settings that are different from the factory default settings are restored to their default settings.
※After confirming the value of the memory switch with the key, press and hold the key to set the default value that is
different from the factory setting.
B:In mechanic memory switch mode, select P124, enter the panel version, and press to initialize the data other than the
following to the factory default settings.
P17-N04 、 P18 、 P19 、 P25 、 P26 、 P32 、 P33 、 P58 、 P59 、 P70 、 P74 、 P75 、 P92 、 P129 、 P144 、 P145 、
P177 ~ P200 、 P235 ~ P242
C:In the mechanic memory switch mode, select P70 and press the key to initialize data other than P92 to the factory default
settings.
※Initialization is performed only when the value of P70 is changed. Therefore, after changing to a value other than the
desired value, it is necessary to return to the desired value.
S-7180A
3. Operation panel
37