7. USING THE SEWING MACHINE (OPERATION PANEL: ADVANCED OPERATION)

7-3. Resetting the data (initialization)

If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been made by
means of memory switches, for instance. In such cases, it may be possible to restore normal operation by following the steps
given below to initialize the memory setting data.
1
While pressing the RESET key, push the POWER switch (1) to the ON side.
4854M
2
Select the initialization level (2) from 1 to 3.
4787M
3
[To carry out initialization]
(Press for 2 seconds or more.)
4
[To exit initialization mode]
Flashing
4857M
Initialization level and settings that are reset or initialized.
Program settings (Parameter)
[P01–P50]
Cycle programs [C1–C9]
Program No.
Cycle step no.
Parameter No.
Memory switch
Production counter
Lower thread counter
Lower thread counter setting value
Operation panel mode
Cutter operation
57
Level 1 is selected as the default.
*
The settings that are reset (initialized) will vary
depending on the initialization level selected. (Refer to
the table below.)
"OPERATING" will be displayed and initialization will start.
*
If you do not wish to carry out the initialization procedure,
press the RESET key.
Normal sewing machine operation will then be possible.
Level 1
Level 2
Default value
Reset
P01
S1
01
Default value
HE-800B
The mode will switch to initialization
mode.
Level 3
Default value
Default value
Program mode
(PROGRAM indicator lights)
Enabled
(CUTTER ON indicator lights)
4927M
4928M
4794M
4917M
Reset
P01
S1
01
0
0
0