Recommended Maximum Current Values For Connection Cables Set - ESAB Aristo RobustFeed U6 Instruction Manual

Table of Contents

Advertisement

5 OPERATION
WARNING!
To prevent the reel from sliding off
the hub, lock the reel in place by
tightening the nut.
CAUTION!
Before threading welding wire, make sure the chisel point and burrs have been
removed from the end of the wire to prevent the wire from jamming in the torch liner.
WARNING!
Rotating parts can cause injury, take great care.
WARNING!
Secure the equipment, especially if used on an uneven or sloping surface.
5.1
Recommended maximum current values for connection
cables set
At an ambient temperature of +77 °F (+25 °C) and normal 10-minute cycle:
Cable area
70 mm²
95 mm²
At an ambient temperature of +104 °F (+40 °C) and normal 10-minute cycle:
Cable area
70 mm²
95 mm²
Duty cycle
The duty cycle refers to the time as a percentage of a ten-minute period that you can weld or
cut at a certain load without overloading.
0463 739 101
Duty cycle
100%
60%
350 A
400 A
400 A
500 A
Duty cycle
100%
60%
310 A
350 A
375 A
430 A
- 18 -
Voltage loss per 10 m
35%
480 A
0.28 V / 100 A
600 A
0.21 V / 100 A
Voltage loss per 10 m
35%
420 A
0.30 V / 100 A
525 A
0.23 V / 100 A
© ESAB AB 2022