Troubleshooting - Baileigh Industrial HSP-50A Operator's Manual

50 ton shop press
Table of Contents

Advertisement

TROUBLESHOOTING

SYMPTOM
Pump is Working But The
Ram Will Not Move.
When Release Valve is
Opened, Ram Does Not
Reset.
Sound From Air Motor
But Ram Does Not Work.
Ram Can Not Complete
Stroke.
Air Motor Does Not
Work.
Leaking oil
POSSIBLE CAUSE (S)
The oil pipe is loose.
The ram is leaking
The oil pipe is loose
Not enough space in the pump.
Ram is damaged
Release valve not completely
closed.
Air in system.
Not enough hydraulic oil.
Not enough air pressure or
exceeded the capacity.
Air motor is damaged.
Damaged or worn out cylinder
seals.
Screwed parts loose.
Damaged hose or hoses.
33
33
CORRECTIVE ACTION
Tighten pipe connections.
Replace the oil seals.
Tighten pipe connections.
Open the exhaust valve.
Replace the ram.
Check and close the release
valve.
Purge the system
Add sufficient oil
Check the air pressure and
capacity.
Replace the air motor. Contact
Baileigh Industrial at
920.684.4990
Replace the seals.
Re-tighten screws.
Contact Baileigh Industrial at
920.684.4990