SECTION 10: SPECIFICATIONS
10.1 GENERAL SPECIFICATIONS
Protection against
ingress of liquids
Protection against
flammable
anaesthetic mixtures
Mode of Operation
EMC General
EMC Susceptibility
EMC Emissions

10.2 POWER

Operating Voltage
Input Fuse Rating
Maximum Power
Requirements
The MAGSTIM Company LTD
This equipment is classified as Class 1, with type BF Applied Parts.
It is designed to comply with the requirements of the Safety Standard
EN60601-1 (90), including amendment 1 (91) and amendment 2 (95) and
EMC Standard EN 60601-1-2, with the exception of immunity clause
36.202.5 "Surges."
2
The Magstim Rapid
System and its accessories are classified as IPXO
(Not Protected), as there is no specialised protection provided against the
ingress of liquids.
Not Protected. Therefore, the Magstim Rapid
are not suitable for use in the presence of a flammable anaesthetic mixture
with air, oxygen or nitrous oxide.
Continuous
2
The Magstim Rapid
System should not be used adjacent to, or stacked
with, other equipment and that if adjacent or stacked use is necessary, the
equipment should be observed to verify normal operation in the
configuration in which it will be used.
2
The Magstim Rapid
System needs special precautions regarding EMC and
needs to be installed and put into service according to the EMC
information provided in Section 11 of this Operating Manual. NB. When
the system is exposed to radiated RF between 80MHz and 100MHz, or
conducted RF between 30MHz and 80MHz, when used with Coil Adapter
P/N 3110-00 and Cooled Coil P/N 3380-00 system errors may occur,
setting system into safe mode.
To avoid interference problems the Magstim Rapid
accessories, should not be used in the vicinity of any equipment that does
not comply with EMC Standard EN 60601-1-2, including portable and
mobile RF communications equipment, such as mobile phones.
The use of accessories, transducers and cables other than those specified by
the Magstim Company Ltd., may result in increased emissions, or
decreased immunity of the equipment. In order to ensure EMC
compliance, the Magstim Rapid
parts specified by the Magstim Company Ltd. for use with the Magstim
2
Rapid
System.
115V±10% AC, 60Hz
230V ±10% AC, 50Hz
240V ±10% AC, 60Hz
2
Rapid
Main Frame
1
Magstim Plus
Equipment should be used with the line cord provided. Where a fused line
cord is used, the appropriate fuse should be fitted.
2
230V/240V Rapid
Systems
Standby
During Discharge
51
2
System and its accessories
2
2
System must be used only with those
1.25A T x 2
250mA T x 2
All Systems
2
Standard Rapid
2
Super Rapid
2
Super Rapid
Plus
MOP03-EN-01
System, and its
20VA
3kVA
6kVA
1
9kVA
June 2011