Fusing temperature protect control

ANIN
CPU
High-temperature
Protect Signal
FUSER_LAMP
FUSER_LAMP_
RY
Controller/Mechanical Control Board
<Soft protect>
• The comparator provided on the Controller/Mechanical Control Board is used as means
for detecting an abnormally high temperature through software approach. If the temper-
ature detected by the Thermistor (voltage value) is greater than the comparative temper-
ature 235 °C (voltage value), the triac relay is turned OFF to shut down the output of the
Heater Lamp.
<Hard protect>
• As a protection should there be a software failure, the Thermostat is used to shut down
current to the Heater Lamp when the temperature of the Fusing Roller becomes inordi-
nately high.