Image reading system: Low image density

<Troubleshooting Procedures>
Step
1
Is the surface of the Original Glass dirty? YES Clean it.
2
Are the Shading Sheet or back surface
of the Original Glass dirty?
3
Are the mirror or lens dirty?
4
Is the Exposure Lamp dirty?
5
Are there no bent connector pins on the
cables connecting the control boards,
are all connectors correctly plugged in,
and are no cables broken?
<Sample of Image Quality Problem>
4011T003AA
Check
T-27
Result
Action
YES Clean them.
YES Clean them.
Replace the Scanner Assy.
YES Clean it.
Replace the Scanner Assy.
NO
Correctly plug in the connectors.
Replace connection cables.