Wall Control Installation - Emerson GEODE CF370PN00 Owner's Manual

52” ceiling fan
Table of Contents

Advertisement

Available languages

Available languages

SINGLE-POLE INSTALLATION
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
NOTE: Make all wiring connections using
wire connectors (supplied). Make sure that all
connections are tight, including ground, and that no
bare wire is visible at the wire connectors, except
for the ground wire.
8.1
Disconnect Electrical Power to the Branch Circuit at the
Circuit Breaker or Fuse Box before attempting to install
the Ceiling Fan Wall Control into the Outlet Box.
8.2
Remove Faceplate and Screws from Existing Wall
Control. Pull Control out from the Wall Box (Figure 33).
Determine the "HOT" Wire and the "LOAD" Wire and
disconnect these Wires from Control (Figure 33).
Do not attempt to disconnect any Wires not already
connected to Existing Control.

8. Wall Control Installation

!
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse or circuit breaker box before
wiring. All wiring must be in accordance with National
and Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.
WALL OUTLET BOX
EXISTING SWITCH
SCREWS (2)
HOT
BLK
NEUTRAL
RECEIVER LOCATED WITHIN
THE CEILING COVER
Figure 33
Please contact 1-800-654-3545 for further assistance
21
WARNING
FACEPLATE
EXISTING
WALL CONTROL
BLACK
GROUND
emersonfans.com
ETL Model No.: CF370

Advertisement

Table of Contents
loading

Table of Contents