Download Print this page

Bompani BI640YB/P Operating And Installation Instructions page 75

Dual fuel freestanding oven

Advertisement

Available languages

Available languages

Adjusting The Reduced Flame Position :
The flame length in the minimum position is adjusted with a flat screw located on the valve. For
valves with FFD, the screw is located on the side of the valve spindle. For valves without FFD, the
screw is located inside the valve spindle. For easier reduced flame adjustment, we advise to remove
the control panel (and microswitch, if present) during adjustment.The position the by pass screw must
be loosened in transformation from LPG to NG. In transformation from NG to LPG, the same screw
must be fastened. Make sure that the appliance is unpluged from the electric current and the gas feed
is open. To determine the min. position, ignite the burners and leave them on in minimum position.
Remove the knobs because the screws are accesible only when the knobs are removed. With the help
of a small screwdriver fasten or loosen the by pass screw around 90 degrees. When the flame has a
length of at least 4mm, the gas is well distributed. Make sure that the flame does not die out when
passing from the maximum position to the minimum position. Create an artificial wind with your hand
toward the flame to see if the flames are stable. For oven burner, operate the oven burner at min.
position for 5 minutes, then open and close the oven door for 2-3 times to check the flame stability of
the burner.
Changing the Gas Inlet
For some countries, the gas inlet type can be different for NG/LPG gases. In such a case, remove the
current connection components and nuts (if any) and connect the new gas supply accordingly. In all
conditions, all components used in gas connections should be approved by local and/or international
authorities. In all gas connections, refer to the "ASSEMBLY OF GAS SUPPLY AND LEAKAGE CHECK"
clause explained before.
Figure 6
Figure 8
Figure 7
Figure 9
9

Advertisement

loading