Bompani BI640YB/P Operating And Installation Instructions page 73

Dual fuel freestanding oven

Advertisement

Available languages

Available languages

50x50 Gas oven
with gas hob
Cable
3x1 mm
crossectional
area
IMPORTANT:
The wires in mains lead are coloured in accordance with the following code:
GREEN and YELLOW ............. EARTH
BLUE ...................................NEUTRAL
BROWN or RED......................LIVE
50x60 full gas oven with gas hob, with gas hob and one hotplate and 60x60 electric oven with
gas hob types free standing ovens with supply cord and plug
This appliance must be installed by a qualified person in accordance with the latest edition of
theIEE regulations and in compliance with the manufacturer instructions
H05VV-F power cable should be used. The cable dimension must be appropriate to above table.
During the electric connection, follow the instructions stated in the user manual. The earthing cable
must be connected to the earth terminal. You have to ensure the power cord with suitable insulation to
be connected to the power source during the connection . If there is no appropriate earthed electric
outlet in accordance with regulations in the place where the appliance will be installed, immediately
contact to our authorized service. The earthed electric outlet must be close to the appliance. Do not
use an extension cord. The power cord must not touch to the hot surface of the product. In case the
cord is damaged, contact Authorized Service to have it changed. Any wrong electric connection may
damage your appliance, as well as endangering your safety, rendering your guarantee invalid. The
appliance is adjusted for 230V 50Hz electricity. If the network electricity is different than this value,
immediately contact your authorized service.
The supply cord should be kept away from hot parts of appliance. Otherwise the cord may be
damaged, causing short circuit. The producer firm declares that it has no responsibility against any
kind of damages and losses that are caused by improper connections that are performed by
unauthorized people.
For protection, you should install an all pole disconnector inside the supply circuit with a contact
opening of at least 3.0 mm rated 32 A and delay functioning type.
50x50 Duel fuel
combined model
(Electric oven with gas
hob)
2
3x1,5 mm
Electrical Connection Diagram
Single-phase
connection
220-240 V~ H05 VV-F
50x50 Duel fuel combined model
(Electric oven with gas hob and one electric
hotplate)
2
3x2,5 mm
L
N
2
7