Download Print this page

Bompani BI640YB/P Operating And Installation Instructions page 70

Dual fuel freestanding oven

Advertisement

Available languages

Available languages

These air holes must have at least the effective cross section of 100cm3 for fresh air circulation
(One or more air holes can be opened.). This hole (or holes) must be opened so that they are not blocked.
Preferably they must be placed close to the bottom and at opposite side of the smokes of the burned gases
that were emptied. If it seems not possible to open these ventilations in the place where the appliance is
set up, the needed air can also be obtained through the next room, provided that this place is not a bed
room or a dangerous place. In this case this "next room" must also be ventilated as required.
Emptying of the Burned Gases from Environment
The cooking appliances that operate with gas, throw the burned gas wastes out directly to the outside
or through the cooker hoods that are connected to the a chimney that opens directly to the outisde. If it
seems not possible to install a cooker hood, it is required to set an electric fan on the window or wall
that has access to fresh air. This electric fan must have the capacity to change the air of the kitchen
environment 4-5 times of its own volume of air per hour
Part 4 : INSTALLATION OF OVEN
There are some factors that must be paid attention to while installing your oven. Surely be very careful
to while installing your oven. Pay attention to our below instructions in order to be able to prevent any
problems and/or dangerous situations that may occur later.
The appliance can be placed close to other furniture on condition that in the area where the oven is
set up, the furniture's height does not exceed the height of the cooker panel. Pay attention not to place
it near the refrigerator, there must be no flammable or inflammable materials such as curtain,
waterproof cloth, etc. that will begin to burn quickly. It is required that there must be least a 2cm blank
space around the oven for air circulation. The furniture close to oven must be manufactured resistant
to temperatures up to 80C. If the kitchen furniture are higher than the hob plate of the oven, it must be
at least 10cm away from the oven's side. The minimum heights from the oven's pan and wall
cupboards and cooker hoods with fan over the oven, are shown as above. Thus, the cooker hood
must be at minimum 650mm height from the cooker pan. If there is no cooker hood, this height must
not be less than 700mm.
4
Cooker hood flue
Air inlet section
2
min. 100cm
Figure 3
Min. 60 cm.
C O O K E R H O O D
Electrical ventilator
Air inlet section
2
min. 100cm
Figure 4
Figure 5

Advertisement

loading