Ground Lug; Table 4: Features: Ethernet Port Rj-45 Pinout (T568B); Figure 6: Description - Connect-Ows Poe Connector Pinout - Redline Connect Series Installation Manuallines

Hide thumbs Also See for Connect Series:
Table of Contents

Advertisement

RDL-3000 Connect-OW-OW
The following table lists the pinout for the Connect-OW/Connect-OW-ER Ethernet port.
Pin
1, 2
3, 6
4, 5
7, 8
Notes:
The PoE does not amplify the Ethernet signal. The maximum total length of the
1.
Ethernet cable is 91.5 m (300 ft). For example, 90 m (295 ft) from the Connect-
OW to the PoE and 1.5 m (5 ft) from the PoE to the local network equipment.
PoE Interoperability: Type 2: 30 W over two pairs, Alternative B: Pairs 4/5 & 7/8
2.

Ground Lug

A ground-lug
terminate a grounding wire. All Connect-OW systems must be properly grounded to
protect against power surges and accumulated static electricity.
70-00200-01-00
Installation Guidelines

Figure 6: Description - Connect-OWS PoE Connector Pinout

Table 4: Features: Ethernet Port RJ-45 Pinout (T568B)

is provided on the Connect-OW chassis. Use this connection to
Proprietary Redline Communications © 2014
Description
Data Pair 1
Data Pair 2
+Ve (in)
-Ve (in)
Page
17
of 58
December 3, 2014