CONNECT-OWS

Figure 12: Description - Connect-OWS PoE Port Pin Assignment

The following table lists the pinout for the Connect-OW/Connect-OW-ER ETH port.
Pin
1, 2
3, 6
4, 5
7, 8
Notes:
The PoE does not amplify the Ethernet signal. The maximum total length of the
1.
Ethernet cable is 91.5 m (300 ft). For example, 90 m (295 ft) from the Connect-
OWS to the PoE and 1.5 m (5 ft) from the PoE to the local network equipment.
PoE Interoperability: Type 2: 30 W over two pairs, Alternative B: Pairs 4/5 & 7/8
2.

Ground Lug

A ground-lug
terminate a grounding wire. All Connect-OWS systems must be properly grounded to
protect against power surges and accumulated static electricity.
70-00200-02-00
Installation Guidelines

Table 13: Features: Ethernet Port RJ-45 Pinout (T568B)

is provided on the Connect-OWS chassis. Use this connection to
Proprietary Redline Communications © 2014
Description
Data Pair 2
Data Pair 3
+Ve
-Ve
Page
23
of 70
December 3, 2014