CONNECT-OWS
4.4.2
Accessing Connect-OWS Management Interface
The Connect-OWS can be configured and monitored using standard Web browser (e.g.,
Firefox or Internet Explorer).
Figure 43: Configuration: Connect-OWS System Configuration Using PC
Web Browser
Configure the IP address of the test PC to be on the same subnet as the wireless
terminal. For example, set the test PC address as follows:
TCP/IP address =
Net Mask =
Use the following steps to establish a Web session with the wireless terminal.
On the PC, open a browser and enter the unit wireless terminal IP address in the
1.
browser address bar. The default address and credentials are:
IP Address: 192.168.25.12
User Name: admin
Password:
70-00200-02-00
Installation Guidelines
192.168.25.5
255.255.255.0
admin
Figure 44: Configuration: Login Screen
Proprietary Redline Communications © 2014
Page
54
of 70
December 3, 2014