Download Print this page

Energizer Beam Series Installer Manual page 5

Crystalline silicon pv modules
Hide thumbs Also See for Beam Series:

Advertisement

4.2 Operational safety measures
During
transportation
packaging damage due to falls or mis-treatment;
ensure that the packaging boxes are ventilated,
protected from the rain and dry; after arriving at
the installation site, carefully open the outer
packaging to prevent scratches and bumps on
the photovoltaic modules due to improper
unpacking.
When
modules, the stacking requirements must be
strictly followed.
Avoid impact or scratches on any part of the
photovoltaic module, otherwise the reliability
and safety of the photovoltaic module will be
affected;
standing
photovoltaic module is prohibited; at the same
time, in order to avoid glass damage, it is
forbidden to apply excessive load or distort
photovoltaic modules.
Installation
and
modules must be done by more than one
person. It is forbidden to pick up, drag, or move
photovoltaic modules by grabbing the junction
box (including the box body, cables, and
connectors). When placing a photovoltaic
module on a flat surface, it must be operated
carefully and care must be taken to not bump
the corners.
When installing or repairing the photovoltaic
system, do not wear any metal accessories to
avoid the risk of electric shock; if it is installed
far above the ground, please wear a safety
harness.
When operating photovoltaic modules in the
sun, please use insulated tools, and wear
rubber gloves and protective clothing. At the
same time, in order to avoid the risk of arc and
electric shock, do not directly touch the junction
box and the end of the output cable (connector)
with your hands.
8 Star Energy Pty Ltd | Level 35, 477 Collins Street, Melbourne VIC 3000 | https://www.energizersolar.com
5
8 Star Energy ESS Ltd | The Black Church, St Mary's Place, Dublin DO7 P4AX, Ireland
and
storage,
avoid
stacking
photovoltaic
or
walking
on
carrying
of
photovoltaic
When the photovoltaic modules are electrically
connected choose a dry and low sunlight period,
preferrably morning or evening; or use opaque
materials to completely cover the surface of the
photovoltaic
generation.
A certain distance between the photovoltaic
module and the installation surface should be
kept to prevent the installation surface from
touching the junction box.
When installing on the roof, comply with the fire
protection requirements of the building. It is
recommended to install photovoltaic modules
on a fireproof and insulated roof covering, and
ensure
adequate
the
photovoltaic
surface. In order to ensure the fire rating on the
roof, the minimum distance between the frame
of the photovoltaic module and the roof surface
is 10 cm.
The connector must be fully mated when wiring.
If the cable is too long, it is recommended to fix
the cable to the installation system with a UV
resistant nylon cable tie. When fixing the cable
to the bracket, the bending radius of the cable
should not be less than 48mm.
Avoid directly exposing cables and connectors
to sunlight. Please use anti-ultraviolet cables.
Do not disconnect the electrical connection
when there is a load.
It is strictly forbidden to try to disassemble the
photovoltaic module, and it is strictly prohibited
to remove the nameplate of the photovoltaic
module or other parts on the photovoltaic
module; it is strictly forbidden to paint or apply
any adhesive on the surface of the photovoltaic
module.
It is strictly forbidden to drill holes in the frame of
the photovoltaic module.
It is strictly forbidden to scratch the anodized
layer on the surface of the aluminum alloy
modules
to
prevent
ventilation
between
modules
and
the
installation
current
the

Advertisement

loading