INSTALLER MANUAL Beam Series Crystalline Silicon PV Modules Installation Manual Version 1.0,Released in November 2021. This guide describes how to install the Energizer Solar Beam crystalline silicon PV modules. To prevent improper operation before use, please carefully read this manual.
Table of contents Table of contents ............................2 Important notes ............................3 Laws and regulations ..........................3 Safety measures ............................3 Handling and unpacking ..........................6 Mechanical installation ..........................7 Electrical installation ..........................12 Maintenance ............................. 14 Modified version and date ..........................15 8 Star Energy Pty Ltd | Level 35, 477 Collins Street, Melbourne VIC 3000 | https://www.energizersolar.com 8 Star Energy ESS Ltd | The Black Church, St Mary’s Place, Dublin DO7 P4AX, Ireland...
2.1 Scope caused by incorrect installation, operation, use and This manual describes the assembly, installation, maintenance of photovoltaic modules and systems. commissioning, maintenance and troubleshooting of Energizer Solar reserves the right to update this Energizer Solar Panels. manual without prior notice.
Page 4
photovoltaic module is connected, can damage affect electrical safety result in loss of life. performance of photovoltaic modules. • It is forbidden to install photovoltaic modules in 4.1 General safety measures windy weather due to safety issues. • Before installation, please contact the relevant •...
Page 5
• modules, the stacking requirements must be When installing on the roof, comply with the fire strictly followed. protection requirements of the building. It is recommended to install photovoltaic modules • Avoid impact or scratches on any part of the on a fireproof and insulated roof covering, and photovoltaic module, otherwise the reliability ensure adequate ventilation between the...
protection equipment that meets It is necessary to protect the safety of photovoltaic requirements. modules when unloading, especially when hoisting roof projects. It is forbidden to use lifting straps • When professionals replace repair directly on the pallet for hoisting. The photovoltaic photovoltaic modules, do not damage the modules should be placed in a protective device and surrounding photovoltaic modules or their...
(such as salt, salt spray, module. salt water, active chemical vapor, acid rain, strong Energizer Solar PV modules adopt high and low steam, or any other substances that will corrode current bins, and the handlers need to place them...
Page 8
hemisphere, modules should typically face lowest point of the photovoltaic module will not north. Dust building up on the surface of the be covered by snow. In addition, it should be modules can impair module performance, 8 ensured that the lowest point of the photovoltaic Star Energy recommends installing the modules module will not be blocked by surrounding trees with a tilt angle of at least 10 degrees, making it...
Page 9
① Place the module on the supporting bars underneath. ② Insert the four stainless-steel bolts (M6) through the holes (7x11.5mm) or stainless-steel bolts (M8) through the holes (9x14mm) in the frame according to the Figure 2, Figure 3, Figure 4 or Figure 5.
Page 10
The clamp must overlap the module frame by at least 8mm but no more than 11mm (The clamp section can be changed under the premise of ensuring reliable installation components). ③ The bar’s top surface contacted with module frame should come with grooves compatible with an M8 bolt.
Page 11
Figure 10 Schematic diagram of side pressing block Figure 11 Requirements for mounting clamps when the guide rails coincide with the long frame Table 2 Installation range and corresponding values Installation method Dimensions Module type Figure L*W*H (mm) Fig 4 Fig 7 Fig 8 Fig 5...
For details of the electrical performance parameters • Refer to Section 690-8 of the National Electrical of Energizer Solar PV modules, please refer to the Code for an additional multiplying factor of PV module product manual. 125% (80% derating) which may be applicable.
Page 13
the maximum open circuit voltage of the photovoltaic system. • When the cable is fixed on the bracket, it is necessary to avoid mechanical damage to the cable or photovoltaic module, and do not press the cable with force. To fix the cable through the proper way, a specially designed tying coil and wire clip must be used to fix it on the bracket.
(Note that the copper wire cannot be attached 7.3 Grounded directly to the aluminum.) Energizer Solar modules use an anodic oxidized • Put the bolt through the cut washer and then aluminum frame to resist corrosion. So the frame of through the hole in the aluminum frame.