WARNING
Caution Using long guards
▶ The long guards must be used when the wire storage extension is fitted. The
standard guards supplied with the machine must otherwise be used.
Note
The emergency stop button must be pressed in before anyone enters the safety area.
1. Bring the guard into position (1).
2. Secure the guard with the retaining pin (2).
5.2.11 Connecting the compressed air lines to the control unit
▶ Connect the compressed air lines to the compressor and control unit.
Note
The emergency stop button must be pressed in before connecting the air lines.
5.2.12 Fitting the water supply
1. Connect the water supply line to the drive unit (3).
2. Connect the hoses for the cooling water lances (1, 2) to the water distributor.
3. Mount the water lances and position the nozzles (2) at the wire entry points.