5.2.7 Fitting the drive unit
1. Pull the clamping bolt (1) out of the carriage.
2. Insert the tensioning hook in the guide slot.
3. Push in the clamping bolt (1) and turn it clockwise until tight (2). Fit the end stop.
5.2.8 Connecting the compressed air lines to the pneumatic cylinder
▶ Connect the compressed air lines (1) to the pneumatic cylinder (2).
5.2.9 Rigging, connecting and pulling the wire through by hand
WARNING
Caution Release the advance unit lock only when the advance pressure cylinder is
not under pressure.
▶ The advance unit lock and piston rod clamp may be released only when you
have made sure that there is no pressure in the advance pressure cylinder.