4. Fine adjustment of the
1.)
The motor adjustment is already pre set at the factory. Through the transport or through soiling on
the sensor or the sensor ring some small speed deviations can occur.
Please check the speed before using the turntable for the first time.
For the correct adjustment of the speed please put the recommended
Testrecord
on the platter. Follow hereby the instruction of the
To check the speed with highest accuracy please use the
www.analogshop.de).
On the front side of your turntable there are three setting trimmers (see Pic. 15).
Pic. 15:
Fine adjustment of the motor (on the
backside)
I f you like to adjust the speed 33 1/ 3 rpm, take the Aluminum screw driver (see accessories) and
turn the left trimmer until you have reached the right speed according to the Stroboscope Testrecord
(see user manual "Stroboscope Testrecord").
-
Turning the trimmer counter clockwise = reduces the turntable speed
-
Turning the trimmer clockwise = raises the turntable speed
Please proceed with the speed adjustment for 45 rpm and 78 rpm in the same way!
Please note:
I f the turntable does not reach the correct speed, the sensor or the scale ring could be dirty or dusty.
To clean the sensor, please take off the platter very carefully!
Clean the sensor and the scale ring with a little isopropyl alcohol and a cotton bud.
Be careful and avoid any scratches on the sensor or the scale ring!
I f the motor has further more speed variations please contact your nearest authorized
dealer or directly the
I f the turntable is not in use, disconnect the unit completely from the power supply by removing the
main plug from the socket.
Now you are finally ready to play your vinyl records.
We wish you a lot of pleasure with your new
Made in Germany
I nnovation
Clearaudio
factory (address on page 14).
motor
Stroboscope Testrecord
Clearaudio Speed Light
- Left trimmer = setting 33 1/ 3 rpm
(near turntable motor)
- Middle trimmer = setting 45 rpm
- Right trimmer = setting 78 rpm