Carrier CDII-184R1-0CTR4 Installation & Operation Manual page 42

Inverter ducted indoor & outdoor unit
Table of Contents

Advertisement

"Fan Speed Selection" are done by "
4.
Speed.
5.
AUTO FAN MODE:
When the Fan is put in auto fan mode, the speed will be varied according to the differences the room
temperature and setting temperature.
If the difference is 3 deg. C or more the speed is high.
If the difference is 2 deg. C or more the speed is medium.
If the difference is 1 deg. C or more the speed is low.
6.
SLEEP (Optional for Remote):
Press SLEEP on remote handset, Symbol
For cool operating mode, the setting temperature will be automatically raised up to 1 deg C after 1
hour.
Repeat above process to exit from this mode.
Note: Sleep mode deactivate if the System is turned off or stopped due to failure.
7.
TIMER ON/OFF (Optional For Remote):
The timer LCD on the Display Unit will show count down hour. (10 minutes to 24 hours).
" Button to Low, Medium, High & Auto Fan
will be shown on handset display.
42