Reference; Alarm; Defrost - Danfoss ERC 21 Series User Manual

Electronic refrigeration control
Table of Contents

Advertisement

Electronic refrigeration control, type ERC 21X
Function
Cooling/Heating (rE=Cooling, Ht= Heating)
Sensor type (n5=NTC 5K, n10=NTC10K, ptc=PTC,
pt1=PT1000)
DO2 config (dEF=Defrost; ALA=alarm; Lig=Light)
(1)
(1)
This option is a default setting in the controller and cannot be changed.
This option is a default setting in the controller and cannot be changed.
(2)
(2)
This parameter can only be set when regulation is stopped, i.e. "r12" is set to 0.
This parameter can only be set when regulation is stopped, i.e. "r12" is set to 0.

Reference

Table 22: Reference
Function
Reference
Setpoint
Differential
Maximum set point limitation
Minimum set point limitation
Display offset
Display Unit (°C/ °F)
Calibration of Sair
Main switch ( -1=Service, 0=OFF, 1=ON,)
Night Set back
Reference displacement offset temperature
Pull down duration
Pull down limit temperature

Alarm

Table 23: Alarm
Function
Alarm
Delay for temp alarm during normal conditions
Delay for temp alarm during pull-down/start up/

defrost

High temp. alarm limit
Low temp. alarm limit
DI1 delay (Time delay for selected DI1 function)
DI2 delay (Time delay for selected DI2 function)
Condenser High alarm limit
Condenser High block limit
Voltage protection enable
Minimum cut-in voltage
Minimum cut-out voltage
Maximum voltage
Defrost
Table 24: Defrost
Function
Defrost
Defrost Method (no=None, nAt=Natural, EL = Elec-
tric; gAS=Hot gas)
Defrost stop temperature.
Defrost Interval
Max defrost Time
Defrost delay at power up
Drip delay
Fan delay after defrost
Fan start temperature after defrost
© Danfoss | Climate Solutions | 2023.01
Code
Min.
Max.
Unit
o07
(2)
rE
Ht
o06
n5
ptc
(2)
o71
(2)
dEF
Lig
Code
Min.
Max.
Unit
r--
r00
-100.0
200.0
°C
r01
0.1
20.0
K
r02
-100.0
200.0
°C
r03
-100.0
200.0
°C
r04
-10.0
10.0
K
r05
-C
-F
r09
-20.0
20.0
K
r12
-1
1
r13
-50.0
50.0
K
r40
-50.0
20.0
°C
r96
0
960
min
r97
-100.0
200.0
°C
Code
Min.
Max.
Unit
A--
A03
0
240
min
A12
0
240
min
A13
-100.0
200.0
°C
A14
-100.0
200.0
°C
A27
0
240
min
A28
0
240
min
A37
0
200
°C
A54
0
200
°C
A72
no
YES
A73
0
270
V
A74
0
270
V
A75
0
270
V
Code
Min.
Max.
Unit
d--
d01
no
gAS
d02
0.0
50.0
°C
d03
0
240
hour
d04
0
480
min
d05
0
240
min
d06
0
60
min
d07
0
60
min
d08
-50.0
50.0
°C
AP0
AP1
AP2
AP3
rE
rE
(1)
rE
(1)
rE
(1)
n10
n10
n10
n10
dEF
ALA
(1)
dEF
(1)
dEF
(1)
AP0
AP1
AP2
AP3
2.0
4.0
2.0
-20.0
2.0
2.0
2.0
2.0
50.0
6.0
4.0
-18.0
-35.0
2.0
0.0
-24.0
0.0
0.0
0.0
0.0
-C
-C
-C
-C
0.0
0.0
0.0
0.0
1
1
1
1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0
0
0
0
0.0
0.0
0.0
0.0
AP0
AP1
AP2
AP3
30
45
30
30
60
90
60
60
8.0
10.0
8.0
-15.0
-30.0
0.0
-2.0
-30
30
30
30
30
30
30
30
30
80
80
80
80
85
85
85
85
no
no
no
no
0
0
0
0
0
0
0
0
270
270
270
270
AP0
AP1
AP2
AP3
EL
nAt
EL
EL
6.0
-
-
-
8
6
8
12
30
45
15
15
0
0
0
0
0
0
0
0
0
0
0
0
-5.0
50.0
(1)
50.0
(1)
50.0
(1)
BC194286421698en-000901 | 25
AP4
AP5
AP6
AP7
rE
(1)
rE
(1)
rE
Ht
(1)
n10
n10
n10
n10
dEF
(1)
dEF
(1)
dEF
ALA
AP4
AP5
AP6
AP7
2.0
-24.0
2.0
50.0
2.0
2.0
2.0
4.0
4.0
-20.0
50.0
70.0
0.0
-26.0
-35.0
30.0
0.0
0.0
0.0
0.0
-C
-C
-C
-C
0.0
0.0
0.0
0.0
1
1
1
1
0.0
0.0
0.0
0.0
0.0
0.0
-
0.0
0
0
-
-
0.0
0.0
-
-
AP4
AP5
AP6
AP7
30
30
30
10
60
60
60
-
8.0
-15.0
8.0
80.0
-2.0
-30.0
-30.0
20.0
30
30
30
30
30
30
30
30
80
80
-
-
85
85
-
-
no
no
no
no
0
0
0
0
0
0
0
0
270
270
270
270
AP4
AP5
AP6
AP7
EL
EL
EL
-
6.0
6.0
6.0
-
8
12
8
-
30
30
30
-
0
0
NA
-
0
0
2
-
(1)
0
0
5
-
(1)
-5.0
-5.0
-
-