Technical Information
Electrohydraulic Actuators PVE-EX

General information

PVE-EX Introduction

Literature Reference

Literature reference for PVG and PVE products
Title
PVG 32 Proportional Valve Groups
PVG 100 Proportional Valve Groups
PVG 32 Proportional Valve Groups
PVG 100 Proportional Valve Groups
PVG 120 Proportional Valve Groups
PVG 32 Metric ports

Product Certification

Protection

Warnings

©
Danfoss | October 2017
The Danfoss PVE-EX is a PVE series 7 actuator for PVG32, PVG100 and PVG120.
The PVE-EX is an explosion proved PVE designed to be used in harsh environments like mining and oil
and gas industries.
The PVE-EX has been certified by NEMKO, IECEx and MA.
The PVE-EX db version is developed according to and in compliance:
EN ISO 4413:2010 Hydraulic fluid power - General rules and safety requirements for systems and their
components
EN 60079-0:2012/A11:2013, IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General
requirements
EN/IEC 60079-1:2014 Electrical apparatus for explosive gas atmospheres-part 1: Flameproof
enclosures "d"
Installation and Maintenance standards:
EN/IEC 60079-14 Explosive atmospheres - Part 14: Electrical installations design, selection and
erection
EN/IEC 60079-17 Explosive atmospheres - Part 17: Electrical installations inspection and maintenance
The PVE-EX is in conformity with listed EU Directive(s):
EMC Directive 2004/108/EC
EN/IEC 61000-6-2:2005 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity
for industrial environments
EN 61000-6-4:2007/A1:2011, IEC 61000-6-4:2006 Electromagnetic compatibility (EMC) - Part 6-4:
Generic standards - Emission standard for industrial environments
All PVE-EX modules comply with protection class IP66 and IP69k according to EN60529. However, in
particularly exposed applications, protection in the form of shielding is recommended.
Before implementing actuators in any application, read all warnings.
Warnings are listed next to the most relevant section and repeated in Warnings chapter.
Type
Service Manual
Service Manual
Technical Information
Technical Information
Technical Information
Technical Information
Order number
11039167
11048807
520L0344
520L0720
520L0356
11051935
BC00000393en-US0102 | 5

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVE 7 Series and is the answer not in the manual?

Questions and answers

Table of Contents