SERVICE MANUAL
5-2.2.
SVCB6 Pre-pick Alarm
Explanation
It was detected by the mechanism controller that none of the following commands from the main
controller is received even after 20 sec have passed since the mechanism controller received the
PREPK (prepick) command:
PSTRT (print start) command
•
TSTRT (test print start) command
•
Troubleshooting Procedure
the printer. Verify all covers
are closed.
Replace main controller PCB.
Verify repairs.
Replace mechanism controller
PCB.
Transfer the NVRAM from the
5-158
Turn off the printer, then turn on
SVCB6 error
still occur?
Yes
SVCB6 error
still occur?
Yes
failed PCB to the new PCB.
Figure 5-15. SVCB6 Pre-pick Alarm Flow Chart
No
Exit!