Download Print this page

Environmental Specifications For All Equipment; Summary Of Printer Optional Features And Feature Specifications - MINOLTA-QMS 4060 Service And Parts Manual

Advertisement

Figure 1-3. 4060 Printer Required Service Area Dimensions
1-2.5.

Environmental Specifications For All Equipment

Table 1-5 lists environmental specifications applicable to the printer, LCH, and LCS units.
Table 1-5. 4060 Printer, LCH Option, and LCS Option Environmental Specifications
Ambient
Condition
Acoustic noise
Dust
Ozone emission
1-3.

Summary of Printer Optional Features and Feature Specifications

Table 1-6 lists the options available with the 4060 printer along with their associated
specifications.
Printer
Operating
Side
33.5 in.
23.0 in.
(850 mm)
(585 mm)
90.0 in.
(2285 mm)
Item
Device condition
Temperature
Humidity
Temperature and
humidity gradients
33.5 in.
(850 mm)
25.2 in.
(640 mm)
25.6 in.
(650 mm)
33.5 in.
(850 mm)
Specification
Operating
Non-operating
10 to 35 °C
0 to 35 °C
20 to 80% RH
20 to 80% RH
(no condensation)
(no condensation)
15 °C per hour or less and 30% RH per day or
less (no condensation)
55 dBA or less (printer only)
3
0.15 mg./m
(stearic acid)
0.1 PPM or less
General Information
SERVICE MANUAL
84.3 in.
(2140 mm)
1-7

Advertisement